Do you have a question about the NTI FTVN150 and is the answer not in the manual?
Lists items included in the LP conversion kit.
Critical safety precautions for carbon monoxide risks.
Step-by-step physical replacement of the natural gas mixer with the LP version.
Adjusts the gas valve throttle screw based on boiler model.
Notes specific fan speed adjustments for 199/199C models.
Prerequisite steps before gas valve and burner setup.
Procedures for measuring and setting gas line pressure.
Steps to set up the combustion analyzer for CO2 measurement.
Check and adjust CO2 levels at maximum boiler output.
Check and adjust CO2 levels at minimum boiler output.
Steps to exit test mode, check for leaks, and reinstall covers.
Document the propane conversion on the appliance.