EasyManua.ls Logo

Numax SBR50 - Page 3

Numax SBR50
6 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MODEL:
SBR50
NUMA.
TOOL
USE
AND
CARE
9
Know
this
tool.
Read
manual
carefully,
learn
its
applications
and
limitations,
as
well
as
the
specific
potential
hazards
related
to
this
tool.
©
Use
only
fasteners
that
are
recommended
for
your
models.
Do
not
use
the
wrong
fasteners
or
load
the
fasteners
incorrectly.
©
Check
for
misalignment
or
binding
of
moving
parts,
breakage
of
parts,
and
any
other
condition
that
may
affect
the
tool's
operation.
If
damaged,
have
the
tool
serviced
before
using.
Many
accidents
are
caused
by
poorly
maintained
tools.
ө
Maintain
tools
with
care.
Keep
tool
clean.
A
properly
maintained
tool,
reduces
the
risk
of
binding
and
is
easier
to
control.
©
Store
tools
out
of
the
reach
of
children
and
other
untrained
people.
Tools
are
dangerous
in
the
hands
of
untrained
users.
9
Check
operation
of
the
tool
before
use.
Do
not
use
the
tool
if
the
workpiece
contact
mechanism
is
not
working
correctly
as
accidental
driving
of
a
fastener
may
occur.
@
Do
not
use
tool
if
trigger
does
not
actuate
properly.
Any
tool
that
cannot
be
controlled
with
the
trigger
is
dangerous
and
must
be
repaired.
©
Do
not
force
tool.
Use
the
correct
tool
for
your
application.
The
correct
tool
will
do
the
job
better
and
safer
at
the
rate
for
which
itis
designed.
©
Use
clamps
or
another
practical
way
to
secure
and
support
the
workpiece
to
a
stable
platform.
Holding
a
tool
by
hand
or
against
the
body
is
unstable
and
may
lead
to
loss
of
control.
©
Keep
the
tool
and
its
handle
dry,
clean
and
free
from
oil
and
grease.
Always
use
a
clean
cloth
when
cleaning.
Never
use
brake
fluids,
gasoline,
petroleum-based
products,
or
any
strong
solvents
to
clean
your
tool.
©
Do
not
use
the
tool
as
a
hammer.
©
Never
use
this
tool
in
a
manner
that
could
cause
a
fastener
to
be
directed
toward
anything
other
than
the
workpiece.
©
Always
carry
the
tool
by
the
handle.
Never
carry
the
tool
by
the
air
hose.
©
Do
not
use
the
tool
if
it
leaks
air
or
does
not
function
properly.
ө
Do
not
operate
the
tool
if it
does
not
contain
alegible
warning
label.
TOOL
SERVICE
©
Use
only
accessories
that
are
identified
by
the
manufacturer
for
the
specific
tool
model.
ө
Use
of
unauthorized
parts
or
failure
to
follow
maintenance
instructions
may
create
a
risk
of
injury.
ө
Use
only
the
lubricants
supplied
with
the
tool
or
specified
by
the
manufacturer.
9
Tool
service
must
be
performed
only
by
qualified
repair
personnel.
OPERATION
©
Do
not
drive
fasteners
near
edge
of
material.
The
workpiece
may
split
causing
the
fastener
or
ricochet,
injuring
you
or
people
around.
©
Do
not
carry
the
tool
from
place
to
place
holding
the
trigger.
Accidental
discharge
could
result.
Choice
of
triggering
method
is
important.
Check
manual
for
triggering
options.
ө
During
normal
use
the
tool
will
recoil
immediately
after
driving
a
fastener.
This
is
а
normal
function
of
the
tool.
Do
not
attempt
to
prevent
the
recoil
by
holding
the
tool
against
the
work.
Restriction
to
the
recoil
can
result
in
а
second
fastener
being
driven
from
the
tool.
Grip
the
handle
firmly
and
let
the
tool
do
the
work.
Failure
to
heed
this
waming
can
result
in
serious
personal
injury.
ө
Do
not
drive
fasteners
on
top
of
other
fasteners
or
with
the
tool
at
an
overly
steep
angle
as
this
may
cause
deflection
of
fasteners
which
could
cause
injury.
©
Do
not
actuate
the
tool
unless
you
intend
to
гіме
a
fastener
into
the
workpiece.
©
Always
handle
the
tool
with
care:
Respect
the
tool
as
a
working
implement.
%
Never
engage
in
horseplay.
%
Never
pull
the
trigger
unless
nose
is
directed
toward
the
work.
Keep
others
a
safe
distance
from
the
tool
while
tool
is in
operation
as
accidental
actuation
may
occur,
possibly
causing
injury.
AIR
SUPPLY
AND
CONNECTIONS
©
The
connector
on the
tool
must
not
hold
pressure
when
air
supply
is
disconnected.
If
an
incorrect
fitting
is
used,
the
tool
can
remain
charged
with
air
after
disconnecting
and
thus
will
be
able
to
drive
а
fastener
even
after
the
air
line
is
disconnected,
possibly
causing
injury.
02
HTTP:/WWW.NUMAXTOOLS.COM
1-888-669-5672
MODEL:
SBR50
МОЛЛУ
@
Do
not
use
oxygen,
combustible
gases
or
bottled
gasses
as
a
power
source
for
this
tool.
Explosion
may
occur,
causing
injury
or
death.
@
Do
not
connect
with
an
air
compressor
which
can
potentially
exceed
200
Psi.
As
tool
may
burst,
possibly
causing
injury.
ө
Always
disconnect
air
resource:
Before
making
adjustments.
When
servicing
the
tool.
When
clean
a
jam.
When
tool
is
not
in
use.
When
moving
to
a
different
work
area,
ав
accidental
actuation
may
occur,
causing
injury.
LOADING
TOOL
©
Do
not
load
the
tool
with
fasteners
when
any
one
of
the
operating
controls
is
activated.
©
Never
place
a
hand
or
any
part
of
body
іп
fastener
discharge
area
of
tool.
©
Never
point
tool
at
anyone.
©
Do
not
pull
the
trigger
or
depress
the
workpiece
contact
as
accidental
actuation
may
occur,
possibly
causing
А
WARNING:
The
warnings
and
precautions
discussed
above
cannot
cover
all
possible
conditions
and
situations
that
may
occur.
It
must
be
understood
by
the
user
that
common
sense
and
caution
are
factors
which
cannot
be
built
into
this
product,
but
must
be
supplied
by
the
user.
UNPACKING
@
This
tool
has
been
shipped
completely
assembled.
ө
Make
sure
that
all
items
listed
in
the
packing
list
are
included.
@
Carefully
remove
the
tool
and
any
accessories
from
the
box.
©
Inspect
the
tool
carefully
to
make
sure
по
breakage
or
damage
occurred
during
shippin
©
Do
not
discard
the
packing
material
until
you
have
carefully
inspected and
satisfactorily
operated
the
tool.
©
if
any
parts
are
damaged
or
missing,
please
call
1-888-669-5672.
PACKING
LIST
Brad
nailer
Air
connector
Adjustment
tools
Lubricating
oil
Instruction
manual
Anti-dust
cap
А
WARNING:
If
any
parts
are
missing
do
not
operate
this
tool
until
the
missing
parts
are
replaced.
Failure
to
do
so
could
result
in
possible
serious
personal
injury.
А
WARNING:
Do
not
attempt
to
modify
this
tool
or
create
accessories
not
recommended
for
use
with
this
tool.
Any
such
alteration
or
modification
is
misuse
and
could
result
in
hazardous
condition
leading
to
possible
serious
personal
injury.
FEATURES
SPECIFICATIONS
Operation
pressure:
|
60-100psi
Nails
capacity:
100pcs
Tool
weight:
2.86
lbs
Air
inlet:
1/4"NPT
Fasteners:
18
Gauge
0.116(2тт)
10mm
15mm
5/8"
20mm
з
2бтт
|
1"
Re
32MM
|
1-4/4"
38
Жат
1/2
T
45mm
1-34
0.041"
50тт
2
(1.05mm)
Compatible
with
Porter
Cable,
Paslode,
Senco,
&
All
Generic
18
Gauge
Straight
Nails.
HTTP:/WWW.NUMAXTOOLS.COM
1-888-669-5672
03

Related product manuals