Nuova Simonelli mac 2000 Specifications

General IconGeneral
Group Heads2 or 3
Boiler MaterialCopper
Boiler Capacity11 liters (2 group), 14 liters (3 group)
Water SupplyPlumbed
Power4500 W (3 group)
Voltage220 V
Steam Wands2
Dimensions (2 group)520 mm
Dimensions (3 group)520 mm

Summary

General Instructions and Safety Warnings

Installation and Electrical Safety

Install by technicians, ensure grounding, sufficient power, and follow safety regulations.

Breakdown and Repair Procedures

Switch off if broken; contact experts only; use original spare parts.

Installation Instructions

Electrical Protection and Wiring

Machine must be protected with an adequately powered automatic switch; check wiring size.

Setting Up the Machine for Operation

Boiler Pressure Adjustment

Adjust boiler pressure via pressure-switch screw for temperature control.

Pump Pressure Adjustment

Adjust pump motor pressure using the pumping element screw.

Steam Dispensing Operation

Pull levers to adjust steam flow; lock in maximum output position.

Espresso Coffee Preparation

Dose Programming Procedure

Program desired coffee quantities using STOP and dose buttons.

Water Softener Regeneration

Cleaning Group with Blind Filter

Use blind filter, detergent, and coffee cycle to clean the group.

Regeneration Procedure Steps

Step-by-step guide to regenerate water softener using salt and specific lever movements.

Trouble Shooting

Unit Lock Indicator and Release

Unit locks if time limit exceeded; red lock LED flashes. Push STOP to release.

Flow Transducer Fault Detection

Fault signalled by flashing LOCK LED and off green LED; blockage occurs if no manual intervention.

Self-Leveling Device Fault Detection

Alarm for max auto-level activation time; disactivates if open > 30s, pump stops. Restart by power cycle.

Programming Espresso Doses (Volumetric)

Dose Programming Procedure

Set desired coffee quantities using STOP and dose buttons; memory is non-volatile.