Group Heads | 2 or 3 |
---|---|
Boiler Material | Copper |
Boiler Capacity | 11 liters (2 group), 14 liters (3 group) |
Water Supply | Plumbed |
Power | 4500 W (3 group) |
Voltage | 220 V |
Steam Wands | 2 |
Dimensions (2 group) | 520 mm |
Dimensions (3 group) | 520 mm |
Install by technicians, ensure grounding, sufficient power, and follow safety regulations.
Switch off if broken; contact experts only; use original spare parts.
Machine must be protected with an adequately powered automatic switch; check wiring size.
Adjust boiler pressure via pressure-switch screw for temperature control.
Adjust pump motor pressure using the pumping element screw.
Pull levers to adjust steam flow; lock in maximum output position.
Program desired coffee quantities using STOP and dose buttons.
Use blind filter, detergent, and coffee cycle to clean the group.
Step-by-step guide to regenerate water softener using salt and specific lever movements.
Unit locks if time limit exceeded; red lock LED flashes. Push STOP to release.
Fault signalled by flashing LOCK LED and off green LED; blockage occurs if no manual intervention.
Alarm for max auto-level activation time; disactivates if open > 30s, pump stops. Restart by power cycle.
Set desired coffee quantities using STOP and dose buttons; memory is non-volatile.