‐EN‐
5
INSTALLATIONANDCONNECTION
Prerequisite
Theunitheadisremoved.(→ Dismantlingtheunit
head)
Set‐uptheunit
Howtoproceed:
B
Onlyinstalltheunitinthepermittedpositionstoen‐
surefault‐freeoperation.
Allowsufficientspaceforcarryingoutmaintenance
work.
Connecttheunit
Howtoproceed:
C
1. Screwthehoseconnectorwithunionnutandseal
ontotheconnectiononthecasing.
– Connecttheinletandoutlet.
– Hand‐tightentheunionnut.
2. Screwthelocknutontothehoseconnector,fitthe
hose onto the hose connector and turn back the
locknuttofixthehoseinplace.
3. On completion of the work, fit the unit head.
(→ Fittingtheunithead)
COMMISSIONING/START‐UP
Prerequisite
• Firstswitchonthepump,thentheUVCclarifier.
• Checkallconnectionsforleaks.
SwitchingON/switchingOFF
• Switchingon:Insertthepowerplugintothesocket.
– Theunitswitchesonimmediately.
• Switchingoff:Disconnectthepowerplug.
Checkthefunction.
D
• The function display is lit when the UVC lamp is
switchedon.
TROUBLESHOOTING
Malfunction Cause Remedy
Theperformanceoftheunitisnotsatis‐
factory
Thewaterisextremelysoiled. Removealgaeandleavesfromtheaquar‐
ium,changethewater.
Thequartzglassissoiled. Cleanthequartzglass.
TheUVClampcapacityisexhausted. Thelampmustbereplacedafter8000op‐
eratinghours.
Flowrateistoohigh. Reducethepumpcapacity.
UVClampisnotlit. Powerplugnotconnected Connectthepowerplug.
UVClampdefective ReplacetheUVClamp.
Connectiondefective Checktheelectricalconnection.
Symbolsusedintheseinstructions
CAUTION
• Indicatesapossiblyhazardoussituation.
• Non‐observance may lead to slight or minor injuries.
NOTE
Indicatesinformationintendedtogivetheuserabet‐
terunderstanding.
Additionalinformation
A Referencetoafigure,e.g.Fig.A.
Referencetoanothersection.
PRODUCTDESCRIPTION
Scopeofdelivery
A
1 Casing
2 Unithead
3 Hosenozzle
4 UVClamp
5 Operatinginstructions
Functiondescription
The special UVC radiation of the UVC clarifier elimi‐
natesfloatingalgaeandotheralgaethatgivewatera
greencolor.Italsokillsbacteriaandothergerms.The
UVCclarifierisintegratedinthewatercircuit,ideally
upstreamofafilter.
Intendeduse
ClearTronic 7 W, referred to in the following as
"unit",mayonlybeusedasspecifiedinthefollowing:
Forcleaningaquariums.
Operationunderobservanceofthetechnicaldata.
Thefollowingrestrictionsapplytotheunit:
• Onlyuseindoorsandoutsideoftheaquarium.
• Donotuseforcommercialorindustrialpurposes.
• Neverusetheunittoconveyfluidsotherthanwa‐ter.
• Nottobeusedforsterilisingdrinkingwaterorother
fluids.
• Donotuseinconjunctionwithchemicals,foodstuff,
easilyflammableorexplosivesubstances.