EasyManuals Logo

Oase Filtoclear 6000 User Manual

Oase Filtoclear 6000
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
- GB -
11
Installation
Fitting hose connections
The max. pump head height is 5m WC (0.5 bar). Only operate the unit with pressure hoses which are approved at least
for 0.2 bar or the maximum pump pressure. Saw off the stepped hose nozzle at the appropriate point of the correspon-
ding hoses (13). Push or screw the hoses onto the stepped hose nozzle and secure with a hose clip.
Installation at the water inlet
Push the union nut over the black stepped hose nozzle, fit the hose, insert the flat sealing ring in the union nut, and
screw onto the water inlet socket.
Installation at the water outlet
Push the union nut over the transparent stepped hose nozzle, fit the hose, insert the green flow indicator flag into the
union nut, and screw onto the water outlet socket.
Installation at the cleaning connection
To permanently fit a drain hose to the cleaning connection, unscrew the cover cap from the cleaning connection, push
the union nut over the transparent hose nozzle, fit the hose, insert the green flow indicator flap into the union nut, and
firmly tighten it on the cleaning connection. During filter operation, ensure that the cleaning connection or a drain hose
connected to it is always closed with the cover cap and the inserted flat sealing ring as a security measure, should the
function switch be unintentionally set to „Cleaning". To close the drain hose with the cover cap, push or turn the black
stepped hose nozzle with its thread onto the hose and secure with the hose clip, firmly screw tighten with the flat se-
aling ring inserted.
Start-up
Attention! Ultra-violet radiation.
Possible consequences: Eye or skin injury from burns.
Protective measures:
Never operate the UVC lamp outside its housing.
Never operate the UVC lamp in a housing that is defective.
Attention! Breakable glass.
Possible consequences: Injury to your hands caused by cuts.
Protective measures: Handle the quartz glass and UVC lamp with care.
Attention! The outlet from the filter cannot be more than 2m (0.2 bar water pressure) vertically above the level
of the filter!
Attention! Never operate the unit without water or without pump strainer casing!
This is how to connect the power supply:
Switching on: Connect the unit to the mains. The unit switches on as soon as the power connection is established.
Switching off: Disconnect the unit from the mains.
Adhere to the safety information given above! Always switch the pump on prior to starting the unit, and check the cor-
rect seating of the connected hoses, the cover cap and the clamping ring with safety latch. The function switch must be
turned to the „Filter“ symbol. Connect the power supply, the blue control lamp is lit. Note: After a new installation, the
unit only reaches its full biological cleaning effect after a few weeks. The full effect on bacteria is only reached as from
an operating temperature of + 10°C.
Note: In the event of overheating, the installed temperature monitor switches the UVC lamp off automatically, the lamp
automatically switches on again once cooled down.
29280-11-14_GA_FiltoClear 3000-611 11 17.11.2014 08:29:51

Other manuals for Oase Filtoclear 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oase Filtoclear 6000 and is the answer not in the manual?

Oase Filtoclear 6000 Specifications

General IconGeneral
BrandOase
ModelFiltoclear 6000
CategoryWater Dispenser
LanguageEnglish

Related product manuals