Replacing the UVC lamp
Change the UVC lamp after approx. 8,000 operating hours. Adhere to the safety information given above! Disconnect
the power supply, switch off the pump and secure against unintentional switching on again. Undo the four screws of
the UVC unit and carefully lift the unit out of the filter cover, unscrew the clamping screw by turning counter-clockwise,
then remove the quartz glass tube including the O ring. Pull out and replace the UVC lamp.
Important! Only use lamps the designation and rating of which match the information on the type plate.
Remove the O ring from the quartz glass and clean, clean the quartz glass tube using a moist cloth, pull out the flat
sealing ring and the protection tube, clean with water.
Check components for damage and replace, if necessary. Reassemble in the reverse order. Start up the pump first,
then connect the unit power supply.
Note!
For safety reasons the UVC lamp can only be switched on when the unit head has been correctly fitted into
the casing.
Wear parts
The UVC lamp, the quartz glass and the foam filters are wear parts and are excluded from the warranty.
Remedy of faults
Trouble shooting Cause Remedy
Water does not clear Unit has been in operation only for a short time
Inadequate pump capacity
Water extremely soiled
Excessive fish and animal population
– Foam filters soiled
Quartz glass tube soiled
The complete biological cleaning effect is only achieved
after several weeks
Readjust the pump capacity
Remove algae and leaves from the pond, perform a
partial water change
Guide value: approx. 60 cm fish length per 1 m³ pond-
water
Clean foam filters
Remove Filtoclear-UVC and clean quartz glass tube
UVC lamp display is not Power supply of Filtoclear-UVC not connected
UVC lamp defective
– Connection defective
UVC lamp capacity exhausted
Protection tube not installed
– Filtoclear-UVC overheated
Function switch turned toCleaning“
Connect power supply of Filtoclear-UVC
Replace the UVC lamp
Check electrical connection
Replace the lamp after approx. 8,000 operating hours
Refer to 'Replace UVC lamp'
UVC automatically switches on when cooled down
Turn function switch to Filter
No water coming from the outlet Pump power supply not connected
– Outlet blocked
Connect pump power supply
– Clean outlet
Storage/Over-wintering
Put the unit out of operation at water temperatures below 8 °C or, at the latest, when freezing temperatures are to be
expected. Drain and thoroughly clean the unit, check for damage. Remove, clean, dry and store all foam inserts in a
frost-free environment. Ensure that the storage place is inaccessible to children. Cover the filter container such that the
ingress of rain water is excluded. Drain all hoses, pipes and connections as far as possible.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Only dispose of the UVC lamp by using the return system provided for this purpose.
29280-11-14_GA_FiltoClear 3000-613 13 17.11.2014 08:29:51

Other manuals for Oase Filtoclear 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oase Filtoclear 6000 and is the answer not in the manual?

Oase Filtoclear 6000 Specifications

General IconGeneral
BrandOase
ModelFiltoclear 6000
CategoryWater Dispenser
LanguageEnglish

Related product manuals