EasyManua.ls Logo

OBERON Arc Flash Suit User Manual

OBERON Arc Flash Suit
7 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
Oberon Arc Flash Suit
User Guide
Oberon Company
22 Logan Street
New Bedford, MA 02740
P: 800-322-3348
F: 508-999-4443
service@oberoncompany.com
www.oberoncompany.com
Oberon Company ▪ 800-322-3348 ▪ service@oberoncompany.com ▪ www.oberoncompany.com
Oberon User Guide
Arc Flash Suit Storage, Use, Care, & Maintenance
Question and Answer IconNeed help?

Do you have a question about the OBERON Arc Flash Suit and is the answer not in the manual?

OBERON Arc Flash Suit Specifications

General IconGeneral
Arc Rating40 cal/cm²
BrandOBERON
StandardsNFPA 70E
Sizes AvailableS, M, L, XL
Includeshood, storage bag

Summary

Oberon Arc Flash Suit Introduction and Overview

Oberon Introduction

Company background and leadership in PPE manufacturing, highlighting technological advancements.

Arc Flash Suit Hood

Detailed description of the arc flash suit hood features, including visibility and protection.

Arc Flash Suit Coat and Bib-Overalls

Information on the construction and compliance of the suit coat and bib-overalls.

Safety, Compliance, and Usage Guidelines

Important Warning

Critical safety notices regarding insulation, protection limitations, and hazard awareness.

Compliance

Oberon PPE compliance with applicable standards like NFPA 70E and CSA Z462.

Care and Use Training

Requirements for care and maintenance of arc-rated clothing and suits.

Remember

Advice to perform risk assessments and select PPE with adequate arc rating.

Storage and Maintenance Procedures

Instructions on Storage

Guidelines for storing the arc flash suit in a clean, dry environment away from sunlight.

Laundry Instructions

General cleaning requirements, including disassembly and fastener care.

Washing Procedures

Detailed instructions for domestic and industrial washing of the PPE.

Detergents and Fabric Softener

Recommendations on appropriate detergents and the prohibition of fabric softeners.

Rinsing, Drying, and Ironing

Steps for rinsing, drying, and the restriction against ironing the garments.

Dry (Chemical) Cleaning

Guidance on when and how to perform chemical cleaning for heavily soiled garments.

Visual Pre-Inspection Guide

Hard Cap Inspection

Checks for shield adapters, cracks, and suspension mechanism functionality.

Hood Inspection

Inspection of the hood window, fabric, rubber washers, and overall condition.

Ventilation System Check

Procedure for checking the ventilation system, including fan operation and battery status.

Coat Inspection

Ensuring the coat fabric is free from damage and closures are functional.

Bib-Overalls Inspection

Checking bib-overalls fabric, suspenders, buckles, and cinch straps for wear.

Donning and Doffing Procedures

How to Put On (Donning)

Step-by-step instructions for donning the arc flash suit components.

Hood Preparation

Steps for preparing the hood, including fan check, disinfection, and cleaning.

Bib-Overalls

Instructions for donning bib-overalls, including visual inspection and suspender adjustment.

Coat

Procedure for putting on the arc flash suit coat and ensuring proper closure.

Other Personal Protective Equipment

Guidance on wearing essential PPE like safety glasses and hearing protection before the hood.

Hood Donning

Detailed steps for putting on the hood, including hard hat adjustment and anti-fog coating.

Gloves

Instructions for donning gloves and ensuring proper cuff overlap with the suit.

Final Check

Final check of suit fit, closures, and hood position after donning.

How to Take Off (Doffing)

Step-by-step instructions for safely removing the arc flash suit components.

Hood Doffing

Procedure for removing the hood, including fan switch-off and cleaning.

Coat Doffing

Instructions for removing the coat and preparing it for storage.

Bib-Overalls Doffing

Procedure for removing the bib-overalls and folding them for storage.

Final Storage Instructions

Storage

Guidance on storing the hood, coat, and bib-overalls in the designated bag.

Final Instructions on Storage

Reinforces storage conditions and includes steps for disconnecting the ventilation fan.