ENGINEERING, INSTALLATION AND SERVICE MANUAL
OWC6012-6032-6034QC
5 Ton Deluxe Portable Water-Cooled
Cooler With Quick Connect
EISM-OWC60QC 10012021
Question and Answer IconNeed help?

Do you have a question about the OCEANAIRE OWC6012QC and is the answer not in the manual?

Summary

ENGINEERING, INSTALLATION AND SERVICE MANUAL

FORWARD

NOTICE

GENERAL INFORMATION

NOMENCLATURE

Explains the model number breakdown for OWC60QC.

CAPACITY RATING

Specifies the cooling capacity of OWC60QC as 60,000 BTU/HR.

WARRANTY

Outlines the limited warranty coverage for Oceanaire products.

WARRANTY CARD

Emphasizes the importance of filling out and returning the warranty card.

SPECIFICATIONS

STANDARD FEATURES

CABINET

Describes the cabinet construction, insulation, and casters.

DELUXE ELECTRONIC CONTROLLER

Details the electronic controller for temperature and fan speed management.

FAN SPEED CONTROL

Explains manual and automatic fan speed settings.

CONDITION ALARM-CON

Describes the "CON" fault code and its causes.

CONDENSATE PUMP

Explains the automatic condensate pump and its operation.

HIGH PRESSURE SAFETY SWITCH

Describes the manual reset high pressure switch for compressor protection.

FILTERS

Explains the washable electrostatic mesh air filter.

POWER CORD

Mentions the 10-foot power cord for convenience.

APPLICATIONS

SPOT COOLER

Describes spot cooling for specific objects or areas.

ROOM AIR CONDITIONER

Explains its use as a room air conditioner with water-cooling advantage.

ELECTRICAL CONFIGURATION

OWC60 QC INTERIOR

INSTALLATION INSTRUCTIONS

RECEIVING-INSPECTION

Advises inspecting the unit and packaging upon receipt.

BEFORE INSTALLING

Recommends checking the unit for damage before installation.

ELECTRICAL REQUIREMENTS

Guides checking nameplate for power requirements and NEMA receptacles.

EXTENSION CORD USAGE

Provides specific guidelines for using extension cords with different models.

ACCESSORIES

Advises verifying and installing accessories correctly.

START-UP

Outlines the initial steps for powering up and testing the unit.

OWC60 QC ACCESSORIES

DISCHARGE AIR NOZZLE KIT ASSEMBLY

Describes the nozzle kit for directing conditioned air to specific areas.

EVAPORATOR RETURN AIR PLENUM

Explains the plenum for ducting return air to reduce noise.

DISCHARGE DUCT ADAPTER

Describes the adapter for connecting round ducts to the unit's discharge.

HK-QC SERIES HOSE KIT

HK-QC INSTALLATION INSTRUCTIONS

HA-LGQC HOSE ADAPTER KIT

DELUXE ELECTRONIC CONTROLLER

OCEANAIRE DELUXE ELECTRONIC CONTROLLER OPERATION

Explains the controller's functions like power, mode, fan speed, and temperature selection.

CONTROLLER PROGRAMMING MENU

PROGRAM SETTINGS

Lists and explains programmable settings P1 through P13.

OWC PROGRAM SETTINGS

NOTICE

Clarifies that program parameters are factory settings, not defaults.

DISPLAY FAULTS

Lists and explains common display fault codes (LAC, AAA, CON).

CHECK UNIT RUN TIME

Provides instructions on how to check the unit's total run time.

WATER VALVE ADJUSTMENT

OWC60 QC REPLACEMENT PARTS PROCEDURE

FAN MOTOR REPLACEMENT

Details the procedure for replacing the fan motor.

ELECTRONIC CONTROLLER REPLACEMENT

Details the procedure for replacing the electronic controller.

POWER MODULE REPLACEMENT

Details the procedure for replacing the power module.

CONDENSATE PUMP REPLACEMENT

Details the procedure for replacing the condensate pump.

HIGH PRESSURE SAFETY SWITCH REPLACEMENT

Details the procedure for replacing the high pressure safety switch.

TROUBLESHOOTING GUIDE

PREVENTIVE MAINTENANCE

OFF SEASON STORAGE-WINTERIZATION

Provides instructions for preparing the unit for off-season storage.

DRAINING WATER LINES AND COIL

Details how to drain water lines and the condenser coil.

DRAINING THE HOSE KIT

Instructions for draining the hose kit.

EVACUATING THE CONDENSATE PUMP

Procedures for evacuating and cleaning the condensate pump.

CLEANING THE UNIT

Advises washing the evaporator coil and allowing the unit to dry.

BLOWER MOTOR

Notes that the blower motor has permanently lubricated bearings.

FILTER

Recommends regular filter inspection, removal, and cleaning.

GENERAL MAINTENANCE ADVICE

States product is not for outdoor use and recommends qualified technicians.

THREE PHASE MONITOR FUNCTION

Explains the three-phase monitor for compressor protection and LED indicators.

PIPING SCHEMATIC

WIRING SCHEMATIC FOR OWC6012 QC

WIRING SCHEMATIC FOR OWC6032 QC

WIRING SCHEMATIC FOR OWC6034 QC

LIMITED WARRANTY

WARRANTY EXCLUSIONS

Lists conditions under which the limited warranty is voided.

WARRANTY CLAIM CONDITIONS

Outlines conditions for warranty claims, like returning defective parts.

END USER INFORMATION

Overview

The OceanAire OWC60QC is a portable water-cooled air conditioner designed for both permanent and temporary spot cooling applications. This self-contained unit features a robust sheet metal cabinet with a gray and blue polyester powder-coated finish, equipped with heavy-duty casters for enhanced mobility. All OWC60QC models come with a 10-foot power cord, further contributing to their portability and ease of setup. The unit is designed to direct cool air to specific areas or objects through a discharge grille located on its upper-front.

Function Description

The OWC60QC operates as a spot cooler, providing targeted cooling in open environments where cooling an entire space is not feasible. It can also function as a room air conditioner, utilizing water for heat rejection. This water-cooled design offers the convenience of connecting water hoses or lines, eliminating the need for condenser air ducts typically associated with air-cooled portable units. The unit is controlled by a solid-state electronic device, offering various temperature and airflow control options to achieve desired comfort levels.

Important Technical Specifications

The OWC60QC series includes three models: OWC6012QC, OWC6032QC, and OWC6034QC, all boasting a cooling capacity of 60,100 BTUH.

  • OWC6012QC: Operates on 208-230V/1 Phase at 60Hz, drawing 23.7 Amps with an in-rush current of 165 Amps. It uses a 6-30P LCDI plug type.
  • OWC6032QC: Operates on 208-230V/3 Phase at 60Hz, drawing 16.5 Amps with an in-rush current of 149 Amps. It uses an L15-30P plug type.
  • OWC6034QC: Operates on 460V/3 Phase at 60Hz, drawing 6.3 Amps with an in-rush current of 75 Amps. It uses an L16-20P plug type.

All models have a total wattage of 5000 and an EER of 12. They feature a 5 HP scroll compressor with varying LRA values (158 for OWC6012QC, 137 for OWC6032QC, and 62 for OWC6034QC). The evaporator CFM (high) is 1950, driven by a 1 HP evap motor. Condenser water flow is 3.8 GPM at 60°F water in and 15 GPM at 85°F water in. Water line connections are 3/4 QC for both inlet and outlet, with a 3/8 QC drain. Condensate removal is automatic via a pump with a 20' vertical lift. The R-410A charge is 52 oz. The unit dimensions are 53.2 inches in height, 28.1 inches in width, and 29.1 inches in depth. Net weight is 375 lbs for OWC6012QC and 410 lbs for OWC6032QC/OWC6034QC. The cooling ambient operating range is 65° to 105°. Time delay fuses/circuit breakers are recommended. The unit is not approved for outdoor use.

Usage Features

  • Deluxe Electronic Controller: The unit is equipped with a sophisticated electronic controller that maintains the desired temperature, with a built-in time delay to protect the compressor from short-cycling. Settings are saved during power outages, ensuring automatic restart.
  • Fan Speed Control: The controller allows for manual or automatic fan speed settings. In manual mode, users can select from six fan speed levels (1-Low to 6-High). In auto mode, the unit adjusts fan speed based on the internal temperature and setpoint.
  • Condition Alarm ("CON"): The LED thermostat displays "CON" to indicate issues such as a failed/restricted condensate pump drain tube, incorrect routing, or interrupted/turned off water supply, all of which disable the compressor.
  • Condensate Pump: An automatic condensate pump removes condensate, discharging through a check valve and a 3/8" male quick connect fitting. It has a 20' lift capability. An overflow switch opens if the pump circuit fails, triggering the "CON" alarm.
  • High Pressure Safety Switch: A manual reset high-pressure switch protects the compressor if the condenser water supply is interrupted. If internal pressure exceeds limits, the compressor cycles off, while the evaporator fan continues to run. Resetting involves pushing a red button in a recessed area.
  • Filters: The unit includes a washable electrostatic mesh air filter at the air intake, located behind the evaporator return air grille, which can be easily removed and cleaned.
  • Hose Kits (HK-QC Series): Quick-Connect (QC) hose kits are available in 10-foot, 25-foot, and 40-foot lengths. They consist of three separate hoses: WATER IN (black, 3/4"), WATER OUT (red, 3/4"), and DRAIN (yellow, 3/8"). These reinforced PVC hoses facilitate connection to a water source and drain, enhancing portability. A QC lanyard is provided to release internal coupling valves for draining hoses. Maximum working pressure for water lines is 100 PSIG. All hose kits come with a 4-Way Sink Adapter Fitting.
  • Hose Adapter Kit (HA-LGQC): This kit allows for connecting garden hoses to the QC-Model unit, useful when the water source and drain are in separate areas or for longer hose runs. It includes Quick-Connect Couplings and garden hose connections.
  • Accessories:
    • Discharge Air Nozzle Kit (2NK-3): Optional kit with two 8-inch diameter nozzles (22" compressed, 32" extended) to direct conditioned air to specific targets, increasing air velocity for cooling personnel or equipment.
    • Evaporator Return Air Plenum (DEP-16): Allows for ducting return air to the evaporator inlet using round duct (flexible or rigid), reducing air noise and offering more cooling solutions. When installed, it's recommended to set the evaporator blower speed to high to prevent coil freeze-up.
    • Discharge Duct Adapter (2DDA-16): Converts the evaporator discharge to a 16-inch diameter round duct for applications requiring ducting of cool air. It can be installed for vertical or horizontal ducting. When used with the DEP-16, it enables closed-loop cooling. High blower speed is recommended to prevent coil freeze-up.

Maintenance Features

  • Preventive Maintenance: Regular maintenance is crucial for prolonging the unit's life and ensuring maximum performance.
  • Off-Season Storage/Winterization: Before storage, the unit should be thoroughly cleaned, and all water drained from the condenser coil, water lines, drain pan, and condensate pump to prevent freezing damage or contamination.
  • Draining Condenser Coil and Interior Water Lines: Detach WATER IN and WATER OUT lines. Use a Shop-Vac to vacuum the WATER OUT line while the unit runs, allowing the water valve to open and drain the condenser coil. Repeat after 15 minutes and depressing the HI PRESSURE RESET until all water is removed.
  • Draining Hose Kit: Disconnect all hoses, connect the lanyard fitting, and allow gravity drainage.
  • Evacuating Condensate Pump: Use a Shop-Vac to remove all water from the condensate pump reservoir. Ensure floats move freely, and check/clean the pump assembly, reservoir, and piping for obstructions or mineral deposits.
  • Cleaning the Unit: Wash the evaporator coil and allow it to dry completely.
  • Blower Motor: Evaporator motors have permanently lubricated bearings and do not require oiling.
  • Filter Maintenance: Inspect the electrostatic mesh air filter regularly (every six weeks or less). Clean by washing in a dishwasher or soaking in warm water and detergent, then rinsing and shaking off excess moisture.
  • Troubleshooting Guide: The manual provides a comprehensive guide for diagnosing and correcting common problems, including power interruptions, thermostat display issues, compressor start failures, and alarms (CON, LAC).
  • Three Phase Monitor (for 3-phase units): Equipped with phase monitors (ICM401/ICM402) to protect the compressor motor against phase reversal, imbalance, or loss. LEDs indicate proper operation (GREEN) or fault conditions (RED).
  • Checking Unit Hours: A procedure is outlined to check the compressor "run" time by disconnecting/reconnecting power and using the controller's arrow down button to display thousands and then direct hours.

OCEANAIRE OWC6012QC Specifications

General IconGeneral
BrandOCEANAIRE
ModelOWC6012QC
CategoryAir Conditioner
LanguageEnglish

Related product manuals