REGULATORS
ALPHA 8 SECOND STAGE
© 2002 Design, 2005
OCEANIC
®
Product Service Guide
Doc. 12-2805-r02 (8/19/10)
PG-10
6. Replace the DIAPHRAGM (15), FRONT COVER (16), and
COVER RING (17), and pressurize the Regulator again with a
pure air source of 3,000 PSI (206 BAR). Inhale lightly through the
Mouthpiece. Air should flow easily and smoothly, without any
hesitation or lag.
NOTE: If hesitation or lag is detected, refer to the Trouble-
shooting Section on page 3 to determine possible cause and
treatment.
7. Clean and disinfect the MOUTHPIECE (18) in warm, soapy
water before returning the Regulator Equipment to the customer.