Conditioning Quick Guide: BIOM® 5 G/55185/0818/en
Product All models and accessories of the BIOM® 5. You will find an itemized list in the Conditioning Instructions BIOM® 5
Notes
This guide is only intended to help you with the cleaning,
disinfection and sterilisation process.
For more detailed information, please refer to the
Conditioning Instructions for the BIOM® 5
Other sterilisation methods must be validated by the
user.
Clean or disinfect the BIOM
®
5 by machine, as this is
much more effective.
Process Instructions Due to the design of the product and the materials used, a
definite limit of the maximum number of conditioning cycles
that can be performed cannot be given. The serviceable life
of the products depends on their function and the care with
which they are handled.
Faulty Products
Before sending: Clean, disinfect and sterilise the
components. Comply with hospital regulations and all
applicable national regulations and laws.
Send the components to OCULUS Service or an
authorized dealer.
Decontamination Preparations No special measures necessary
Preparations at the Site of Use Detach the BIOM ® 5 from the microscope
Preparations at in the conditioning station
Dismantle the BIOM ® 5
Transport and Storage Safe storage in a closed container and transport of the products to the conditioning location
Pre-Cleaning Material: Cold water, water pistol
Procedure:
Place the BIOM® 5 in cold water for five minutes. The BIOM® 5 must be fully covered.
Flush out gaps, joints and cavities (the marked locations) for fifteen seconds with the water pistol.
Cleaning/Disinfection Cleaning/disinfection by machine
Material: CDU (with therm. disinfection programme, 5 min-
utes at 90°C, for A
0
value=3000), detergent CDU, cold wa-
ter, demineralised water
Procedure:
3 Minute pre-wash cycle with cold water
Empty
5 Minute cleaning cycle at 55°C with neodisher
MediClean (concentration 0.5%, Dr. Weigert, Hamburg)
Empty
3 Minute rinse cycle with cold, demineralised water
Empty
2 Minute rinse cycle with demineralised water
Empty
Check whether the BIOM
®
5 needs to be dried off with
compressed air
Manual cleaning/disinfection
Material: Cleaning solution with 0.8% detergent (Cidezyme/
Enzol from Johnson & Johnson), water
Procedure:
Check that the components have no visible signs of
soiling.
Place the components in the cleaning solution for
5 minutes at 40°C. The BIOM® 5 must be fully covered.
Rinse the components for 5 seconds under running water
(static pressure 4.2 bar).
Optional: Clean in an ultrasonic bath
.