5. Basic parameter setting and information
By selecting SETUP, the functional parameter settings is visualized
Press ENTER Browse the various
options by means of the
buttons UP and DOWN
Icon Meaning Description
DATE /TIMESetting of date and
time
It is possible to regulate date and time The set data are
automatically stored when you exit the menu
LANGUAGESetting of used
language
By selecting this option it is possible to choose the language
visualized on display Press ENTER to confirm and exit.
LCD SETTINGS
To increase / decrease the contrast and the brilliance of the display
HOSES SETTING Setting of
used working tube length,
choice of gas residuals
treatment (suction into the unit
vs. suction in the A/C system)
Select to choose the length of the hoses. The default length is 3 m,
max length is 10 m
NOTE: If the hose length is set to “0” (zero), at the end of the
working cycle, the unit will lead the user to suction the gas
residuals in the A/C system of the vehicle, instead of
recovering them into the unit
OIL VISCOSITY Setting of ithe
viscosity of the oil to be injected
For the adjustment of the opening time of the oil injection valve
(according to higher/lower viscosity of oil to be injected and to the
environment temperature) .This regulation is only necessary for
models without oil scales. The default setting is a parameter of
100, it is possible to adjust (increase or decrease ) this value and,
consequently, the opening time of the oil solenoid valve.
File transfer
Selecting this option the unit is ready to receive the files of data
bank up-dates. The unit signalizes the receipt of the data. For the
use of the up-dating Software please refer to the specific
instructions
Information and statistics in use
for the unit
Displays informations and the software version of the unit as listed
below
5.1 Hoses setting
Select to choose the length of the hoses currently in use in order the unit to be able to calculate the
refrigerant quantity which remains in the charging hoses. The default length is 3 m, max length is 10 m
Press ENTER Increase the hose length
by means of the buttons
UP and DOWN
(set “0” to suction the gas
residuals in theA/C syst
NOTE: If the hose length is set to “0” (zero), at the end of the working cycle, the user will have to
suction the gas residuals in the A/C system of the vehicle, instead of recovering them into the unit.
Ecos-150 sw 1.x.x - ver. 1.0