Do not install, remove, or reinstall the unit by yourself (customer).
Thereisriskofre,electricshock,explosion,orinjury.
For installation, always contact the dealer or an Authorized service center.
Thereisriskofre,electricshock,explosion,orinjury.
Be sure the installation area does not deteriorate with age.
If the base collapses, the air conditioner could fall with it, causing property
damage, product failure, and personal injury.
Install the unit securely in a place which can bear the weight of the unit.
Donotinstalltheunitinaplacewhereaammablegasleaks.
- - - - - - - - - - - - - - - - - - - - - - - - - - -
2.1.1 -
Minimum room area in the case of
2.2 - CHECKS TO PERFORM BEFORE INSTALLATION
a. Checks at the area
Beforestartingtoworkonthesystemscontaininginammablerefrigerants,safety
checks are necessary to reduce the risk of ignition to a minimum.
To repair a refrigeration system, the following precautions must be complied with
before working on the system.
b. Work procedure
The job must be performed according to a controlled procedure in a way to reduce
the risk of the presence of inammable gas or vapour to a minimum during the
performance of the job.
c. General work area
All maintenance personnel and those working in the local area, must be trained
regarding the job performed.
Do not work in tight spaces.
Refrigerant gas load as per technical data label (without additional load)
MONO
0,62 0,67 1,8 2 2
0,62 0,67 0,6 4 4
Refrigerant gas load with MID additional load
MONO
0,74 0,79 1,8 2 2
0,74 0,79 0,6 5 6
Refrigerant gas load with MAXIMUM additional load
MONO
0,86 0,91 1,8 2 2
0,86 0,91 0,6 7 8
Model
Quantity of refrigerant gas
(kg)
Height of
installation
(m)
Minimum room area
(m
2
)
Size 9 Size 12 Size 9 Size 12