3.5.6 - Operation in “Ventilation” mode only
• Whenusedinthismodetheairconditionerdoesnotperformanyactionwithregardtotemperatureand
airhumidityintheroom.
• Toactivatethismode,presskeyB4ontheremotecontrolseveraltimesuntiltheautomaticventilation
symbol D1 appearsontheremotecontroldisplay.
3.5.7 - Operation in “Spa” mode only (Automatic)
• Inthismode,themachine’stemperatureisautomaticallyregulatedaccordingtotheroom’stemperature.
Thefanspeedisalsoautomaticallyregulatedaccordingtothesettemperature(exceptindehumidication
mode).
• Toactivatethismode,presstheB4keyontheremotecontrolseveraltimesuntiltheD7 symbol appears
onthedisplay.
3.5.8 - Operationin“Heating”modeonly(onlymodelsttedwithheatingpump)
• Usingthismode,theapplianceheatstheroom.
Thisfunctionisonlyavailablefortheversionswithheatpump(HP).
• Toactivatethismode,pressbuttonB4ontheremotecontrolseveraltimesuntiltheD2 symbol appears
onthedisplay.
• Inthisrunmode,therequiredtemperatureandfanspeedcanbeset.Afterthreeminutes(maximumtime)
thecompressorshouldstartandtheairconditionerstartsheatingtheroom.
• ThestartofthecompressorisindicatedbythelightingupoftheLED B(green)locatedontheconsole
(g.40).
The air conditioner has to defrost its battery periodically.
During this operation the air conditioner does not heat the room, though its internal
parts remain on except for the room air fan. when the outdoor temperature is very
low, there may be a slight delay for passage from the minimum to the medium or
maximum speed from when the command is sent to the machine with the remote
control.
Like delays might occur on activating the swinging function of the mobile bafe.
After having turned off the unit, the internal fan runs seconds more. Then it stops
and both air aps close.