UNICO EDGE R32
LED D LED B H
LED C LED A
G
EN - 35
ENGLISH
Table “TAB1”
DESCRIPTION
LED D
green
LED C
yellow
LED B
green
LED A
red
Signallingofthemachineinstand-by OFF OFF OFF OFF
Signallingofthemachineinoperation ON x x x
Signallingoftimeractivation,machineonhold OFF ON OFF OFF
Signallingoftimeractivation,machinerunning ON ON x x
Signallingoftheignitionoftherefrigeratorcompressor ON x ON x
Indicationofanyneedtocleantheairlter. ON x x ON
ON: led on - OFF: led off - x: indifferent
4.3.4 - Console alarms
Inthepresenceofanalarm,theLEDsashasindicatedintable “TAB2”.
Ifoneofthealarmspersistsformorethanthreeminutes,contactanOlimpiaservicecentre.
Table “TAB2”
DESCRIPTION
LED D
green
LED C
yellow
LED B
green
LED A
red
Externalairtemperatureprobefaulty x x 0 1
Condensertemperatureprobefaulty x x 0 2
Inlettemperatureprobefaulty x x 0 3
Compressorcurrentprotection x x 0 4
Communicationerror x x 0 5
Powerlineovercurrent x x 0 6
Compressorcurrentprotectionnotsuitable x x 0 7
PowerboardDCvoltageproblem x x 0 8
Currentanomaly x x 0 9
Condensertemperaturetoohigh x x 1 0
UIPM protection x x 1 2
EEPROM reading error x x 1 3
EEPROMwritingerror x x 1 4
Inlettemperaturetoohigh x x 1 7
Roomtemperatureprobefaulty 0 1 0 0
Evaporatortemperatureprobefaulty 0 2 0 0
Evaporatortemperaturetoolow 0 3 0 0
Evaporatortemperaturetoohigh 0 4 0 0
Communicationerror 0 5 0 0
Evaporatingfanmotorfailure 0 8 0 0
Waterlevelalarm 1 1 0 0
1-9: number of ashes (1 ash = 1 second on, 1 second off) - 0: led off - x: indifferent