4.3 - DIAGNOSIS, ALARMS AND INCONVENIENCES
4.3.1 - Diagnosis of the inconveniences
ItisimportantfortheUsertodistinguishbetweenfunctionalproblemsandanomaliesinrelationtothebehaviour
oftheapplianceasforeseenforitsnormaloperation.Furthermore,themostcommonproblemsmayeasily
besolvedthroughsimpleoperationsonbehalfoftheUser(Seeparagraph4.3.5-Anomaliesandsolutions).
For all the other reports (see paragraph: 4.3.3 - 4.3.4), it is necessary to always
contact the technical assistance service”
Any attempt to repair the appliance by unauthorised personnel will immediately
invalidate any form of guarantee.
4.3.2 - Functional aspects not to be mistaken for anomalies
Thefollowingeventsmayoccurduringnormaloperation:
a. The compressor does not start up again immediately after a stop (it takes about three minutes
to start again).
- Intheoperatinglogicoftheapplianceadelaybetweenacompressorstopanditssuccessiverestart
hasbeenincluded,sothatthecompressoritselfisprotectedagainstactivationsthataretoofrequent.
b. Duringtheheatingoperationoftheheatpumpappliances,theowofhotairmayoccursome
minutes after activation of the compressor.
- Shouldthefanstartatthesametimeasthecompressor,fortherstfewminutesitwouldemitcold
airintotheroom(andthiscouldbothertheoccupants)sincetheunithasnotyetreachedsteady
runningconditions.
4.3.3 - Console led signals
Intheeventthattheairconditionerisblocked,theLEDs
highlightanalarmsignalaspertable“TAB1”.
ContactanOlimpiaservicecentre.
H Resetkey.
G Infraredreceiver.