4.2 - MAINTENANCE
Ifyouplantoidletheunitforalongtime,performthefollowing:
a. Stoptheairconditioneranddisconnectthepowersupply.
b.Removethebatteriesfromtheremotecontrol.
Do not perform them alone.
4.2.1 - Routine maintenance
Theairconditionerthatyouhavepurchasedhasbeendesignedtoreduceroutinemaintenanceoperations
toaminimum.
Theseoperationsinvolvesolelythecleaningoperationsoutlinedbelow:
• Cleaningorwashingoftheambientairlterevery2weeksoreverytimetherelativeredLEDlightsup
(thiscanbedonebytheuser,seeusermanual).
• Cleaningofthecondensingbatteryandcleaningofthecondensatemanagementsystem.
Theseoperationsmustbecarriedoutbyskilledtechniciansonaregularbasisthatwilldependontheplace
ofinstallationandintensityofuse.
Dependingonthequantityofdirt,theunitcanbecleaneddry(byusingabatterycompressorandbowl
andcleaningthenswithasoftbrushtakingcarenottodeformthem)ormorethoroughlyusingdedicated
detergents.
Beforeyouleavethesiteofinstallationyoushouldgatherupallpackingmaterialanduseadampclothto
removeanytracesofdustthatmayhavedepositedonthemachineduringassembly(g.33).
Theseoperations,thoughcertainlynotessential,haveabenecialeffectastheyenhancetheprofessional
imageoftheinstallerintheeyesoftheclient.
Topreventunnecessarycallsbytheuser,beforeyouleavethesiteofinstallation
• itisalsoagoodideato:
• ExplainthecontentsoftheInstructionManualtotheuser.
• Showtheuserhowtocleanthelter.
4.2.2 - Condensation water drainage in case of emergency
Ifanomaliesoccurinthecondensationwaterdisposalsystem,theairconditionerstopsandsignalsthealarm
statuswiththeintermittentlightingupofLED A,LED B and LED C(g.40).
Toenabletheairconditionertoworktemporarilyuntiltheservicepersonnelarrive,youcandrainthewater
outbyfollowingthesesimpleinstructions(g.38):
Before proceeding with any maintenance and cleaning,
always make sure the system has been switched off, using
the remote control, and the power supply plug has been
disconnected from the system socket (or the upstream
master isolating switch is positioned at “0” OFF).
a. Removethebottomcover.
b. Removethecap(6a)afterhavingplacedagood-sizedcontainerunderneathit(atleast5-litercapacity)
tocollectthewater.
c. Afterhavingclearedthefault,theservicepersonnelwillclosetheevacuationpipe.