UNICO EDGE R32
EN - 33
ENGLISH
4.2 - MAINTENANCE
Ifyouplantoidletheunitforalongtime,performthefollowing:
a. Stoptheairconditioneranddisconnectthepowersupply.
b.Removethebatteriesfromtheremotecontrol.
Do not perform them alone.
4.2.1 - Routine maintenance
Theairconditionerthatyouhavepurchasedhasbeendesignedtoreduceroutinemaintenanceoperations
toaminimum.
Theseoperationsinvolvesolelythecleaningoperationsoutlinedbelow:
• Cleaningorwashingoftheambientairlterevery2weeksoreverytimetherelativeredLEDlightsup
(thiscanbedonebytheuser,seeusermanual).
• Cleaningofthecondensingbatteryandcleaningofthecondensatemanagementsystem.
Theseoperationsmustbecarriedoutbyskilledtechniciansonaregularbasisthatwilldependontheplace
ofinstallationandintensityofuse.
Dependingonthequantityofdirt,theunitcanbecleaneddry(byusingabatterycompressorandbowl
andcleaningthenswithasoftbrushtakingcarenottodeformthem)ormorethoroughlyusingdedicated
detergents.
Beforeyouleavethesiteofinstallationyoushouldgatherupallpackingmaterialanduseadampclothto
removeanytracesofdustthatmayhavedepositedonthemachineduringassembly(g.33).
Theseoperations,thoughcertainlynotessential,haveabenecialeffectastheyenhancetheprofessional
imageoftheinstallerintheeyesoftheclient.
Topreventunnecessarycallsbytheuser,beforeyouleavethesiteofinstallation
• itisalsoagoodideato:
• ExplainthecontentsoftheInstructionManualtotheuser.
• Showtheuserhowtocleanthelter.
4.2.2 - Condensation water drainage in case of emergency
Ifanomaliesoccurinthecondensationwaterdisposalsystem,theairconditionerstopsandsignalsthealarm
statuswiththeintermittentlightingupofLED A,LED B and LED C(g.40).
Toenabletheairconditionertoworktemporarilyuntiltheservicepersonnelarrive,youcandrainthewater
outbyfollowingthesesimpleinstructions(g.38):
Before proceeding with any maintenance and cleaning,
always make sure the system has been switched off, using
the remote control, and the power supply plug has been
disconnected from the system socket (or the upstream
master isolating switch is positioned at “0” OFF).
a. Removethebottomcover.
b. Removethecap(6a)afterhavingplacedagood-sizedcontainerunderneathit(atleast5-litercapacity)
tocollectthewater.
c. Afterhavingclearedthefault,theservicepersonnelwillclosetheevacuationpipe.