1-OLIO.
·
Controllarelostatodicontaminazioneodiinvecchiamento
dell’olio.
L’oliocontaminatoèlacausaprincipaledelmalfunzionamentodel
-
levalvoleediunabreveduratadellepompeadingranaggi.
OGNI12MESI...
1-CONTROLLOGENERICO
·
Controllovisivodituttiicomponentidicarpenteriaedeimecca
-
nismialfinediverificarel’assenzadiinconvenientiedieventuali
anomalie.
2-IMPIANTOELETTRICO.
·
Fateeffettuaredaparteditecnicielettricispecializzati(INTER
-
PELLAREILCENTROASSISTENZA)uncontrollodell’impianto
elettrico,comprensivodimotoredellacentralina,cavi,finecorsa,
quadrocomando.
3-OLIOIMPIANTOIDRAULICO.
Effettuarelasostituzionedell’olio,provvedendocomesegue:
·
Abbassareilsollevatorefinoallaquotaminima(aterra).
·
Assicurarsicheilcilindroidraulicosiaafinecorsa.
·
Toglierealimentazionealpontesollevatore.
·
Procedereascaricarel’oliodalcircuitoidraulico,svitandoiltap
-
popostonellaparteinferioredelserbatoiodellacentralina.
·
Richiudereiltappodiscarico.
·
Procederealriempimentodellacentralina,immettendol’oliodal
tappopostonellapartesuperioredelserbatoiodellacentralina
stessa.
·
L’oliodeveesserefiltrato.
·
Caratteristicheetipid’oliosonoriporatinellespecifichetecniche
(cap.2,pag.10).
·
Richiudereiltappodicarico.
· Alimentareilpontesollevatore.
·
Faredueotrecorsedisalita-discesa(perunaaltezzadicirca
20-30centimetri)perimmetterel’olionelcircuito.
nelcambiodell’olio:usaresoloolioraccomandatooequiva-
lente;nonusareoliodeterioratodalungagiacenzainmagaz-
zino.
Losmaltimentodell’oliodeveesserefattocomeindicato
nell’appendice“A”.
EVERY6MONTHS...
1-OIL
Checktheoilforcontaminationorageing.
Contaminatedoilisthemaincauseofvalvemalfunctionsandwill
reducetheworkinglifeofthegearpumps.
EVERY12MONTHS...
1-GENERALINSPECTION
·
Visualinspectionofallstructuralandmechanicalpartstoassure
thatallisfault-freeandingoodcondition.
2-ELECTRICALSYSTEM
·
Havetheelectricalsystem,includingmotor,wiring,limitswit
-
ches,andcontrolpanel,checkedoverbyaspecialisedelectri
-
cian(CONTACTTHESERVICECENTRE).
3-HYDRAULICSYSTEMOIL
Changetheoilasfollows:
·
Lowertheliftcompletely.
·
Makesurethatthehydrauliccylinderisfullyretracted.
·
Disconnectthepowersupply.
·
Draintheoilfromthecircuitbyunscrewingthedrainplugatthe
bottomofthereservoir.
·
Refitthedrainplug.
·
Fillthereservoirthroughthefillerholeonthetop.
·
Makesuretheoilisfiltered.
·
Foroiltypesandcharacteristicsrefertothetechnicalspecifica
-
tions(chapter2,page10).
·
Closethefillerplug.
·
Connectthelifttothepowersupply.
·
Performtwoorthreelift—loweringcycles(toaheightof20-30
cm)inordertofillthecircuitwithoil.
Oilchanges:useonlyrecommendedoilbrandsorequiva-
lents;neveruseoilthathasdeterioratedbecauseofexcessi-
velylongstorage.
Disposeofusedoilasindicatedinappendix“A”.