EasyManua.ls Logo

Omega RD100B - Page 89

Omega RD100B
234 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-12
Setup Item Pen/Dot Selectable Range or Selections Default Value
Math > Color > Color Dot Model Purple/Red/Green/Blue/Brown/Black Purple: 0A/0G
Red: 0B/0J
Green: 0C/0K
Blue: 0D/0M
Brown: 0E/0N
Black: 0F/0P
Math > Output pen > Pen CH Pen Model Pen: 1 to 4, Channel: 01 to 04/0A to 0J 1pen: 01, 2pen: 02,
3pen: 03, 4pen: 04,
Math > Print2 > CH - 0A/0B/0C/0D/0E/0F/0G/0J/0K/0M/0N/0P 0A
Math > Print2 > Mode - AVE/MIX/SUM/MIN/MAX/INST AVE
Math > Print2 > SUM scale - Off, /s, /min, /h, /day Off
Math > Bar graph > CH - 0A/0B/0C/0D/0E/0F/0G/0J/0K/0M/0N/0P 0A
Math > Bar graph > Graph - Normal/Center Normal
Math > Error data > Error - +Over/–Over +Over
Math > Error data > Over - Skip/Limit Skip
RS-422A/485 communication interface function (/C3 option).
Setup Item Pen/Dot Selectable Range or Selections Default Value
RS-422/485 > Address - 1 to 32 1
RS-422/485 > Baud rate - 1200/2400/4800/9600/19200/38400 9600
RS-422/485 > Data length - 7/8 8
RS-422/485 > parity - Odd/Even/None Even
RS-422/485 > Protocol - NORMAL/MODBUS NORMAL
Ethernet communication interface function (/C7 option)
Setup Item Pen/Dot Selectable Range or Selections Default Value
Ethernet > Host > Host - 64 characters or less Blank
Ethernet > Host > Domain - 64 characters or less Blank
Ethernet > Local IP > A - IP address 0.0.0.0
Ethernet > Local IP > M - IP address (Subnet mask) 0.0.0.0
Ethernet > Local IP > G - IP address (Default gateway) 0.0.0.0
Ethernet > DNS > DNS - On/Off Off
Ethernet > DNS > P - IP address (Primary DNS sever) 0.0.0.0
Ethernet > DNS > S - IP address (Secondary DNS sever) 0.0.0.0
Ethernet > DNS > Suffix_P - Primary domain suffix Blank
Ethernet > DNS > Suffix_S - Secondary domain suffix Blank
Ethernet > Login > Login - Use/Not Not
Ethernet > LoginSet > Level - Admin/User1 to User6 Admin
Ethernet > LoginSet > Register - On/Off Admin and User1
are On
Ethernet > LoginSet > User - 16 characters or less Admin: admin
User1 to 6: user1 to
user6
Ethernet > LoginSet > Password - 4 characters or less Administrator: 0
User1 to 6: 1 to 6
Ethernet > Timeout > Timeout - On/Off Off
Ethernet > Timeout > Duration - 1 to 120 min 1 min
Ethernet > K. Alive > Keep alive - On/Off On
Adjustment
Setup Item Pen/Dot Selectable Range or Selections Default Value
P_Adj > P_Adj Dot Model Hysteresis/Zero/Full Hysteresis
Pen Model Zero/Full Zero
P_Adj > Pen No. Pen Model 1/2/3/4 1
Store
Setup Item Pen/Dot Selectable Range or Selections Default Value
End > End - Store/Abort Store
4.3 Menu Structure, Settings, and List of Default Values

Table of Contents

Related product manuals