14 Programmable Controllers SYSMAC CS1G/H
Functions Added by Unit Version
The following functions have been added for the unit versions of CS1G/H CPU Units.
OK: Supported, ---: Not supported
Unit Versions
Unit versions have been introduced to control differences in
functions featured by CPU Units that are the result of version
upgrades.
The unit version is marked on the nameplates of products subject
to version control, as shown in the diagram.
Unit Versions and Programming Devices
Model CS1@-CPU@@H
Function Unit version No unit version Unit version 2.0 Unit version 3.0 Unit version 4.0
Downloading and Uploading Individual Tasks --- OK OK OK
Improved Read Protection Using Passwords --- OK OK OK
Write Protection from FINS Commands Sent to CPU Units via
Networks
--- OK OK OK
Online Network Connections without I/O Tables --- OK OK OK
Communications through a Maximum of 8 Network Levels --- OK OK OK
Connecting Online to PLCs via NS-series PTs
OK
(from lot number 030201)
OK OK OK
Setting First Slot Words
OK
(for up to 8 group)
OK
(for up to 64 group)
OK
(for up to 64 group)
OK
Automatic Transfers at Power ON without a Parameter File (.STD) --- OK OK OK
Automatic Detection of I/O Allocation Method for Automatic
Transfer at Power ON
--- --- --- OK
Operation Start/End Times --- OK OK OK
Support of
new
instructions
MILH, MILR, MILC --- OK OK OK
= DT, <>DT, <DT, < = DT, >DT, > = DT --- OK OK OK
BCMP2 --- OK OK OK
GRY
OK
(from lot number 030201)
OK OK OK
TPO --- OK OK OK
DSW, TKY, HKY, MTR, 7SEG --- OK OK OK
EXPLT, EGATR, ESATR, ECHRD, ECHWR --- OK OK OK
IORD/IOWR reading/writing to CPU Bus Units
OK
(from lot number 030418)
OK OK OK
PRV2 --- --- --- OK
Function blocks (CX-Programmer Ver.5.0 or later) --- --- OK OK
Serial Gateway (converting FINS commands to CompoWay/
F commands at the built-in serial port)
--- --- OK OK
Comment memory (in internal flash memory) --- --- OK OK
Expanded simple backup data --- --- OK OK
TXDU(256), RXDU(255) (support no-protocol communications with
Serial Communications Units with unit version 1.2 or later)
--- --- OK OK
Model conversion instructions: XFERC(565), DISTC(566),
COLLC(567), MOVBC(568), BCNTC(621)
--- --- OK OK
Special function block instructions: GETID(286) --- --- OK OK
Additional
instruction
functions
TXD(236), RXD(235) (support no-protocol
communications with Serial Communications Units
with unit version 1.2 or later)
--- --- OK OK
Use of new
special
instructions
Conversion instructions from numbers to ASCII
and ASCII to numbers
--- --- --- OK
Flowchart conversion instructions (one type of
block programming instructions) to convert
flowchart programs from C-series Flowchart PLCs
to ladder programs for CS/CJ-series PLCs
--- --- --- OK
Function
block (FB)
functional
upgrades
Online editing of function blocks --- --- --- OK
Support for I/O variables (including array variables
for I/O variables)
--- --- --- OK
Support for STRING data type and processing
functions for ST language.
--- --- --- OK
Applicable PLCs Name CX-Programmer
CS1G/H-series
CS1H-CPU67H/66H/65H/64H/63H
CS1G-CPU45H/44H/43H/42H
No unit version Version 2.1 or later
Unit version 2.0 Version 4.0 or later
Unit version 3.0 Version 5.0 or later
Unit version 4.0 Version 7.0 or later
Unit version
Unit

Related product manuals