132
Power Solid-state Relay
G3PA-(VD)
Extremely Thin Relays Integrated with
Heat Sink
Downsizing achieved through optimum design of
heat sink.
Mounting possible via screws or via DIN rail.
Close mounting possible for linking terminals.
(Except for G3PA-260B-VD.)
Applicable with 3-phase loads.
Replaceable power element cartridges.
Conforms to VDE 0160 (finger protection), with a
dielectric strength of 4,000 V between input and
load.
Conforms to VDE 0805, IEC 950.
Approved by UL, CSA, and VDE.
RCW
Ordering Information
Model Isolation Zero
cross function
Indicator
Applicable output load Rated input voltage
G3PA-210B-VD
Phototriac
l
Yes Yes
10 A at 24 to 240 V
AC
5 to 24 VDC
G3PA-220B-VD
oo ac
coupler
es
es
20 A at 24 to 240 V
AC
5o C
G3PA-240B-VD
40 A at 24 to 240 V
AC
G3PA-260B-VD
60 A at 24 to 240 V
AC
G3PA-210BL-VD
No
10 A at 24 to 240 V
AC
G3PA-220BL-VD
o
20 A at 24 to 240 V
AC
G3PA-240BL-VD
40 A at 24 to 240 V
AC
G3PA-260BL-VD
60 A at 24 to 240 V
AC
G3PA-210B-VD
Yes
10 A at 24 to 240 V
AC
24 V
AC
G3PA-220B-VD
es
20 A at 24 to 240 V
AC
C
G3PA-240B-VD
40 A at 24 to 240 V
AC
G3PA-260B-VD
60 A at 24 to 240 V
AC
G3PA-420B-VD
20 A at 180 to 400 V
AC
12 to 24 VDC
G3PA-430B-VD
30 A at 180 to 400 V
AC
oC
G3PA-420B-VD-2
20 A at 200 to 480 V
AC
G3PA-430B-VD-2
30 A at 200 to 480 V
AC
G3PA-450B-VD-2
50 A at 200 to 480 V
AC
Question and Answer IconNeed help?

Do you have a question about the Omron G3PA-260B-VD and is the answer not in the manual?

Overview

The OMRON G3PA-(VD) is a series of power solid-state relays designed for various industrial applications, offering compact size and robust performance. These relays are characterized by their extremely thin design, integrating a heat sink for efficient thermal management and enabling downsizing.

Function Description

The G3PA-(VD) series functions as a power solid-state relay, controlling AC loads with a DC or AC input signal. It utilizes phototriac couplers for isolation between input and output. The series includes models with and without zero-cross function, which helps to reduce noise and extend the life of the load by switching the output when the AC voltage crosses zero. Some models are specifically designed for 3-phase loads, and the power element cartridges are replaceable, allowing for easier maintenance and extended product life.

Important Technical Specifications

The G3PA-(VD) series offers a wide range of output load capabilities and input voltage options.

  • Output Load:

    • Load Voltage: Models are available for 19 to 264 VAC (50/60 Hz), 150 to 440 VAC (50/60 Hz), and 180 to 528 VAC (50/60 Hz).
    • Load Current: The series covers a broad range from 0.1 A to 60 A, with specific models handling 10 A, 20 A, 30 A, 40 A, 50 A, and 60 A.
    • Inrush Current: The relays are designed to withstand significant inrush currents, with values up to 440 A (60 Hz, 1 cycle) for higher current models.
    • Output ON Voltage Drop: Typically 1.6 V (RMS) max. for lower voltage models and 1.8 V (RMS) max. for higher voltage models.
    • Leakage Current: Ranges from 5 mA max. (at 120 VAC) to 20 mA max. (at 400 VAC), depending on the model and load voltage.
    • I²t: Ranges from 260 A²S to 810 A²S.
  • Input Voltage:

    • DC Input: 5 to 24 VDC, with a voltage range of 4 to 30 VDC. Input current impedance is 7 mA max. or 20 mA max.
    • AC Input: 24 VAC, with a voltage range of 19.2 to 26.4 VAC. Input current impedance is 1.4 kΩ ±20%.
    • Must Operate Voltage: 4 VDC max. for DC input models, 19.2 VAC max. for AC input models, and 9.6 VDC max. for higher voltage DC input models (e.g., G3PA-420B-VD).
    • Must Release Voltage: 1 VDC min. for DC input models and 4.8 VAC min. for AC input models.
  • Isolation and Dielectric Strength:

    • Isolation Method: Phototriac coupler.
    • Dielectric Strength: 4,000 VAC, 50/60 Hz for 1 min, ensuring high insulation between input and load.
    • Insulation Resistance: 100 MΩ min. (at 500 VDC).
  • Environmental Ratings:

    • Operating Temperature: -30°C to 80°C (with no icing or condensation).
    • Storage Temperature: -30°C to 100°C (with no icing or condensation).
    • Ambient Humidity: 45% to 85% operating.
    • Vibration Resistance: Malfunction: 10 to 55 Hz, 0.75-mm double amplitude (mounted to DIN rail).
    • Shock Resistance: Malfunction: 300 m/s² (mounted to DIN rail).
  • Compliance: Conforms to VDE 0160 (finger protection), VDE 0805, IEC 950. Approved by UL, CSA, and VDE. Conformance to EN55011 is possible with a capacitor connected to the load power supply.

Usage Features

  • Mounting Flexibility: The G3PA-(VD) relays can be mounted via screws or on a DIN rail, offering versatility in installation.
  • Close Mounting: Close mounting is possible for linking terminals, which is beneficial for space-saving, though specific models (e.g., G3PA-260B-VD) may have limitations. When close mounting up to three units, the load current must be reduced by 10% for G3PA-210B-VD, -220B-VD, -240B-VD, and by 20% for other models. For four or more units, a minimum clearance of 10 mm between each SSR is required.
  • Vertical Mounting: For vertical mounting, the load current must be 30% lower than the rated one. A distance of 3 cm or more between the G3PA (especially the SSR on the upper side) and the duct is recommended.
  • Horizontal Mounting: Screw or DIN track mounting is possible, with horizontal mounting to ground. For horizontal mounting, a distance of 80 mm between the upper SSR and the lower SSR should be maintained.
  • Indicator: An operation indicator and temperature indicator are included for easy monitoring of the relay's status.
  • Linking Terminal: Linking terminals are provided for connecting multiple SSRs, simplifying wiring in multi-unit installations.
  • Noise Terminal Voltage: Conformance to EN55011 is possible if a capacitor is connected to the load power supply.

Maintenance Features

  • Replaceable Power Element Cartridges: A key maintenance feature is the replaceable power element cartridge (G32A-A Power Device Cartridge). This allows for easy replacement of the triac circuitry if it malfunctions due to excessive current, without needing to disconnect the wiring from the G3PA unit.
  • Temperature Indicator: The temperature indicator on the power device cartridge changes from pink to red if the triac circuitry has malfunctioned, signaling the need for replacement.
  • Special Tool for Cartridge Replacement: For specific models (G3PA-210B-VD/-220B-VD), a special tool is provided to extract the cartridge, simplifying the replacement process. For other models, screws secure the cartridge.
  • Silicone Grease Application: When mounting a new power device cartridge, it is crucial to apply silicone grease (provided with the G32A-A) to the entire surface of the heat radiator. This improves heat radiation efficiency and ensures proper operation.
  • Cleanliness: Before mounting, ensure there is no dust or wire pieces on the heat radiator of the G32A-A or the G3PA to prevent malfunctions.
  • Power Off During Replacement: Always turn off the power supply when replacing the cartridge to prevent malfunction or damage.
  • Terminal Cover: The terminal cover should be attached after maintenance to prevent accidents due to electric shock.

Omron G3PA-260B-VD Specifications

General IconGeneral
TypeSolid State Relay
CategoryRelays
Mounting StyleDIN Rail
Load Current60 A
Output Current60 A
Zero CrossYes
Operating Temperature-30 to 80 °C
Package / CaseModule
Isolation Voltage4 kV
Contact Rating60 A
Max Switching Voltage264 VAC
Max Switching Current60 A
Contact FormSPST-NO
Insulation Resistance1000 MΩ min.
Dielectric Strength4, 000 VAC
Operating Time1/2 cycle of load power source + 1 ms max.
Release Time1/2 cycle of load power source + 1 ms max.
Terminal TypeScrew
Storage Temperature-30 to 100 °C
Vibration Resistance10 to 55 Hz