Section 1 Outline of Macro Function
1-5
NS series Macro Referenc
e
Execution conditions for the functional objects
Macro execution conditions that can be made for each functional object are described in the
following table.
Open property dialog for each functional object and select [Macro] tab page, then set the
execution condition and create macro.
For details on registering macros, refer to the online CX-Designer Help ‘Creating Functional
Objects’.
Execution condition Explanation
Touch on Timing Execute when functional object is pressed.
Touch off Timing Execute when functional object is released
Before Inputting numeral or character
string
Execute just before display tenkey pad or virtual
keyboard for inputting values or strings
Before Writing numeral or character
string
Execute just before notice numeral and character
string to the host.
When changing numeral and character
string and comparing numeral
Execute when changing the value of address.
When Processing Display Area Execute when display area for alarm display is
pressed.
When Selecting an Alarm/Event Execute just after select each alarm/event displayed
on Alarm/Event Summary
When selecting a list Execute just after select a list displayed on the List
Selection.
Note
If the password is set for functional objects, the following macros are executed after
inputting the password. If the password has been cancelled for inputting, macros will not
be executed.
- Touch on/Touch off timing
- Before inputting Numeral/Character string
- When pressing Display Area
- When selecting an Alarm/Event
- When selecting a list