A - 125
Appendices
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
A-3 Sysmac Error Status Codes
A
A-3-2 Error Description
Event name Object Corrupted Event code 14AB 0000 hex
Description The checksum data in non-volatile memory is corrupted.
Source
EtherCAT Master Function Module
Source
details
Slave
Detection
timing
When
establishing
communications
after turning ON
power to the slave
Error
attributes
Level
Minor fault
Recovery
Error reset
(after cycling slave
power)
Log category
System
Effects
User program
Continues. Operation Power drive circuit is OFF for relevant slave.
Indicators
EtherNet/IP NET RUN EtherNet/IP NET ERR EtherNet/IP LINK/ACT
–––
System
-defined
variables
Variable Data type Name
None – –
Cause and
correction
Assumed cause Correction Prevention
Non-volatile memory failure Replace the Servo Drive. None
Attached
information
None
Precautions/
Remarks
“37” is displayed on the Servo Drive front panel and F037 is given as the AlarmCode (4001 hex).
Event name Object Corrupted Event code 14AC 0000 hex
Description The checksum data in non-volatile memory is corrupted.
Source
EtherCAT Master Function Module
Source
details
Slave
Detection
timing
When
establishing
communications
after turning ON
power to the slave
Error
attributes
Level
Minor fault
Recovery
Error reset
(after cycling slave
power)
Log category
System
Effects
User program
Continues. Operation Power drive circuit is OFF for relevant slave.
Indicators
EtherNet/IP NET RUN EtherNet/IP NET ERR EtherNet/IP LINK/ACT
–––
System
-defined
variables
Variable Data type Name
None – –
Cause and
correction
Assumed cause Correction Prevention
Non-volatile memory failure Replace the Servo Drive. None
Attached
information
None
Precautions/
Remarks
“37” is displayed on the Servo Drive front panel and F137 is given as the AlarmCode (4001 hex).