RFID System
User's Manual
(Modbus TCP)
Section 1 Application Flowchart
Section 1
Product Overview
17
p.89
Setting Reader/Writer Communications Conditions
Change the network settings of the host device to match those of the Reader/Writer.
Host Device Setting Example
IP address: 192.168.1.100
Subnet mask: 255.255.255.0
he default network settings for the Reader/Writer are listed in the following table.
IP address 192.168.1.200
Subnet mask 255.255.255.0
Default gateway 192.168.1.254
Port number 502
Port number for Web browser 7090
Start a web browser (e.g., Internet Explorer) on the host computer, enter http://192.168.1.200/ in the address box, and press the
Enter Key. Communications will be possible if the following view appears.