89
RFID System
User's Manual
(Modbus TCP)
Section 5 Setting Communications Conditions
Section 5
Preparations for Communications
Setting Communications Conditions
Initial Setting Procedure
Default TCP/IP Network Settings in the Reader/Writer
The default network settings for the Reader/Writer are listed in the following table.
Change the network settings of the host device to match those of the Reader/Writer.
Host Device Setting Example
IP address: 192.168.1.100
Subnet mask: 255.255.255.0
This example changes the last part of the IP address of the host device to a value other than 200 (i.e., 1 to 199 or 201
to 254). Values of 0 and 255 cannot be used.
Refer to Configuration in Section 8 Browser Interface for Initial Setting method for the Reader/Writer.
p.224
List of Settings
Setting Procedure for Web Server
Enter the settings on the Network Settings display and then click the Set Button.
Refer to Network Settings View in Section 8 Browser Interface for Initial Setting method.
p.212
IP address 192.168.1.200
Subnet mask 255.255.255.0
Default gateway 192.168.1.254
Port number 502
Port number for Web browser 7090