EasyManua.ls Logo

Omron V680S-HMD63-ETN - Page 65

Omron V680S-HMD63-ETN
338 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RFID System
User's Manual
(Modbus TCP)
Section 3 Component Names
Section 3
Component Names
63
V680S-A42 @M
Reader/Writer connector
This connector connects to the connector on the Reader/Writer or to the V680S-A40 @M Extension
Cable.
Ethernet Connector Lines
These lines are connected to an Ethernet connector to supply power and the control signal to the
Reader/Writer. The Reader/Writer supports for Auto-MDIX, can communicate by both straight and
cross ethernet lines.
If an Ethernet network is configured into a loop as shown below, broadcast packets are accumulated in the band, and the
communication is disabled. Therefore, do not configure the Ethernet network into a loop.
When a large amount of broadcast packets or multicast packets flow into the Ethernet network, Reader/Writers may stop its
operation. Please do not send a large amount of packet. Please separate the Reader/Writers from the network segment that
broadcast or multicast packets flow.
Reader/Writer connector
Ethernet connector lines
Sending broadcast storm
Reader/Writer
HUB
HUB
HUB
Broadcast storm
Communication disabled