76
Section 4 Installation
RFID System
User's Manual
(Modbus TCP)
Section 4
Installation and Connections
V680-D8KF67
Mount the RF Tag with M3 screws.
Tighten the screws to a torque of 0.6 N·m.
Refer to RF Tag Installation Precautions in Section 11 Appendices for information on the effect of metal at the back surface,
Mutual Interference of RF Tags and Influence of Inclination of the V680-D8KF67.
p.273
V680-D8KF67M
Mount the V680-D8KF67M to a metal surface.
Mount the RF Tag with M3 screws.
Tighten the screws to a torque of 0.6 N·m.
When you install the RF tag, prepare the metal plate as shown in the figure below.
When the metal plates size is larger than the below illustration, communication range will change.
Please confirm the influence well.
Although it is possible to use SUS, aluminum or brass in addition to steel as metal plate, communications range is
influenced by the material. Do not use resin as metal plate.
Refer to RF Tag Installation Precautions in Section 11 Appendices for information on the effect of surrounding metal, Mutual
Interference of RF Tags and Influence of Inclination on the V680-D8KF67M.
p.273
Marked side
M3 screw
Mounting Hole Dimensions
Two, M3 holes
32
±0.2
32±0.2
Marked side
M3 screw
Mounting Hole Dimensions
Two, M3 holes
32
±0.2
32±0.2
25±0.2
25±0.2
Screw mounting
Metal plate
V680-D1KP66MT
34
(Unit: mm)
34
Material: Steel
Two, M3 holes