EasyManua.ls Logo

Onkyo TA-RW111

Onkyo TA-RW111
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TA-RW111
ADJUSTMENT
PROCEDURES
PRECAUTIONS
1.
Before
adjustment,
clean
the
following
parts
with
an
alchol
moistend
swab.
*
record/
playback
head
*
erase
head
*
pinch
roller
*
capstan
2.
Do
not
use
magnetized
screwdriver
for
adjustmenis.
3.
Demagnetize
record/
playback
head
with
a
liead
de-
magnetizer.
Tape
speed
adjustment
TEST
EQUIPMENT
/
TOOLS
REQUIRED:
Audio
oscillator
Digital
frequency
counter
Oscilloscope
Attenuator
AC
voltmeter
Non-magnetic
screwdriver
Test
tapes
TCC-153
10kHz,
—15dB
MTT-II11
:3kHz,
—10dB
MTT-150
:Dolby
level
calibration
400Hz,
tone
200nWb/m
Connect
the
digital
frequency
counter
to
the
line
output
terminal.
Load
the
test
tape
MTT-111
into
the
cassette
holder.
Connect
the
test
point
TP-2
to
the
ground
to
be
the
unit
to
adjustment
mode.
Press
the
forward
play
button.
(The
unit
becomes
the
high
speed.
)
Adjust
the
trim
resistors
R802(Deck
A)
and
R817(Deck
B)
so
that
the
frequency
counter
reading
becomes
6000Hz
to
6020Hz.
Press
the
forward
play
button.
(The
unit
becomes
the
normal
speed.
}
Adjust
the
trim
resistors
R803(Deck
A)
and
R818(Deck
B)
so
that
the
frequency
counter
reading
becomes
3000Hz
to
3010Hz.
Item
Connection
of
Line
input
|
Test
tape}
Mode
,
Output
Adjustment
Adjust
instrument
indicator
point
4
—>———
um
i
i
——_
_
ccm
+
—s
AC
voltmeter
ue
.
Maximum
and
Head
and
oscillo-
|
AC
Head
azimuth
h
1
eae
scope
to
TCC-153
|
PB
voltmeter
|
05
2414
Same
phase
azimuth
LINE
output
Oscilloscope
|
@ore™
at
channels
+
OurpO
Ns
coP
LandR
terminal
+
]DECK
A
_|
AC
voltmeter
R117
(ch.
L)
2
|)
LayPack
|
+5
terminals
MTT-150|PB
AC
Rek
Be
level
voltmeter
|
DECK
B
TP
R119
(ch.
L)
R120
(ch.
R)
B;
Frequency
METAL
Fre
3p
oy|
Counter
to
TAPE
|REC
vee
|
b-403
85kHz+
2kHz
requency|
1549
XS-C90
counter
Repeat
the
recording
IkHz,
23dB
Same
level
and
play
back
4
[Bias
fig-2
and
Gog
(REC/PBIAG
oe
Ri
at
1kHz
and
|
until
the
1kHz
and
"
12kHz,
-
23dB
12kHz 12kHz
playback
signals
are
same
level.
REC
AC
Attenuator
or
350mV
Record
.
UD-1
voltmeter
|
AF
OSC
output
bs)
fig-2
1kHz
level
C-90
REC
Ppl
AC
R219
(ch.
L)
|
Same
level
voltmeter
|
R220
(ch.
R)
at
REC/PB
Blank
tape
NORMAL
::::::
UD-1
C-90
PLAY
torque-:::+++++*:
30--
70g
//
em
HIGH
«+
++++e
++
XL-II
C-90
FF.
REW
torque
:::::80~-180¢//
cm
METAL-::::---:-
XS
C-60
Back
tention
--++-++++"++°-
6~12¢
7
cm

Related product manuals