6E- 58 1973 OPEL SERVICE MANUAL
Figure
6E-34
Leaf Spring Installed
1
6E-36
Figure 6E-36 Checking Vent Valve Adjustment
39. Check compression of vent valve lower spring. It
should be compressed
l/4
inch with throttle valve
completely closed. See Figure
6E-36.
40. Correct by bending valve lever.
Figure
6E-35
Installing Cover Gasket
SPECIFICATIONS
GENERAL SPECIFICATIONS
Compression Ratio
........................................................................................................
7.6 to 1
Fuel Required
................................
(.
..........................................................................
Low Lead
Fuel Tank Capacity (Gallons)
Opel 1900 and Manta..
....................................................................................................
11.9
GT.. ................................................................................................................................. 13.2
Fuel Gauge Type
........................................................................................................
Electrical
Fuel Pump Type
......................................................................................................
Mechanical
Fuel Pump Drive
..................................................................................
Eccentric on Camshaft
Fuel Pump Pressure at 1950 RPM
......................................................................
3.1 to 3.7 psi
Fuel Filter
............................................................................................................
In-Line Filter
Carburetor
Make
and
Type
................................................
I-Solex
2
BBL Automatic Choke
Air Cleaner Element Type
..........................................................................
Fiber Mesh
-
Paper