CD33-30N(P) CD33-50N(P) CD33-85N(P) CD33-120N(P) CD33-250N(P)
①Press the Select button more than 5 seconds.
②
CD33-30N(P)A CD33-50N(P)A CD33-85N(P)A CD33-120N(P)A CD33-250N(P)A
③
CD33-30N(P)V CD33-50N(P)V CD33-85N(P)V CD33-120N(P)V CD33-250N(P)V
④
CD33-30N(P)-422 CD33-50N(P)-422 CD33-85N(P)-422 CD33-120N(P)-422 CD33-250N(P)-422
①
CD33-30CN(P) CD33-50CN(P) CD33-85CN(P) CD33-120CN(P) CD33-250CN(P)
②
CD33-30CN(P)A CD33-50CN(P)A CD33-85CN(P)A CD33-120CN(P)A CD33-250CN(P)A
③
CD33-30CN(P)V CD33-50CN(P)V CD33-85CN(P)V CD33-120CN(P)V CD33-250CN(P)V
④
CD33-30CN(P)-422 CD33-50CN(P)-422 CD33-85CN(P)-422 CD33-120CN(P)-422
②Teach indicator lights up showing that Run status changes to Teach status.
30mm 50mm 85mm 120mm 250mm
±4mm ±10mm ±20mm ±60mm ±150mm
0.15×0.15mm 0.6×1.2mm 0.9×1.5mm 1.2×1.8mm 1.5×2.5mm ③Function indicator lights up.
0.1×0.1mm 0.5×1.0mm 0.75×1.25mm 1.0×1.5mm 1.75×3.5mm
0.15×0.15mm 0.4×0.9mm 0.6×1.0mm 0.5×0.8mm 2.0×4.5mm
7.5ms max.
18ms max.
54ms max. ④Select function by pressing Select button.
●Control panel
⑤Adjust or select value of function you need by pressing Set button.
⑥Then return to RUN by pressing by pressing Select button continuously 5 seconds.
●S
ut
Dual output Analogue Voltage RS422 ①Press simultaneously both the Select button and Set button for 5 seconds.
CD33- ① CD33- ② CD33- ③ CD33- ④
RS422
②Both Run and Teach indicators come up.
RS422
③Function indicator Q1 lights up.
※Q2 lights up when it's RS422 type.
④Select a function by pressing Select button.
⑤Adjust or select the function by pressing Set button.
⑥Then return to RUN by pressing by pressing Select button and Set button continuously
5 seconds.
Type
Cable type
Connector type
Center
Measuring range
Light source Red laser Diode (wave length 655nm)
Peak power Max. output 1mW
Laser Class
IEC/JIS CLASS2
FDA CLASSⅡ
Spot size
(approx.
volume)
*1
Near
Middle
Far
Linearity *2
Sampling period
±0.1% F.S.
(F.S.=8mm)
±0.1% F.S.
(F.S.=20mm)
±0.1% F.S.
(F.S.=40mm)
±0.1% F.S.
(F.S.=120mm)
±0.3% F.S.
(F.S.=300mm)
Resolution *3
2μm
(Fast:4μm)
5μm
(Fast:8μm)
10μm
(Fast:15μm)
30μm
(Fast:45μm)
75μm
(Fast:150μm)
Response
time
Fast averaging: 1 time 5ms max.
Standard averaging: 16 times 12.5ms max.
High resolution averaging: 64 times 36.5ms max.
500 ,750(250mm type) /1000 /1500 /2000μs
Temperature Drift ±0.08% F.S./℃
Indicators
Distance Indicator
Bar graph LED Analogue
Output Indicator
ON status : Orange
MF (multi functional) input
Laser off、Remote teaching、Sample Hold (choose one function)
Response time :3ms max.
Sun light: 10,000 lx max. / Incandescent lamp: 3,000 lx max.
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 h for XYZ axes
Shock resistance
Circuit protection Reverse polarity、Over current
Protection Category IP67
Operating temp./humidity -10~+45℃/35~85%RH (No condensation or freezing)
Storage temp./humidity -20~+60℃/35~95%RH (No condensation or freezing)
Ambient Light
50G (500m/s
2
)
Warm up period 15min max.
Material PBT (Case) PMMA (Front window)
Weight
Cable type Approx. 65g (without cable)
Connector type
Approx. 70g
Type
Supply Voltage
DC12~24V
(+10%/-5%)
DC18~24V
(+10%/-5%)
DC12~24V
(+10%/-5%)
Current Consumption
55mA max. (DC24V)
85mA max. (DC24V)
including analog output
value
55mA max. (DC24V)
-
Voltage Dual Output
Control output
Q2
NPN/PNP Open collector 100mA max. /30V DC
(Residual voltage 1.8 V max.)
Analog output - 4~20mA 0~10V -
Interface -
Outputs
Control output
Q1
NPN/PNP Open collector 100mA max. /30V DC
(Residual voltage 1.8 V max.)
Connection
Cable type *4
φ5 5core 2m
cable(PVC) AWG24
φ5 6core 2m cable(PVC) AWG24
φ5 8core 2m
cable(PVC) AWG24
Connector type
M12 8pin
Analog ground wire is not equipped for connector type. Therefore connect the analog
ground terminal of analog input equipment and the 0V terminal of power supply.
Distance indicator has seven LEDs. LED indicate distance by moving at near to far side.
Status of LED Status of measurement Indicator
Out of range.
*This LED indicate when due to too
high/low reflection
Both side of red LED
lights up
MF (multi functional) input activates when connected to GND(-) for NPN type,
and when connected to (+) for PNP type.
Object is near of range.
Near side of red LED
lights up
Object is far of range.
Far side of red LED
lights up
Object is some far of range.
Far side of green LED
lights up
Object is middle of range.
Middle of orange LED
lights up
INSTRUCTION MANUAL
● It is dangerous to wire or attach/remove the connector with the power
on. Make sure to turn off the power before operation.
●Installing in the following places may result in malfunction:
1. A dusty or steamy place
2. A place generating corrosive gas
3. A place directly receiving scattering water or oil.
4. A place suffered from heavy vibration or impact.
●The product is not designed for outdoor use.
●Do not use the sensor in a transient state at power on(Approx. 15min.
Warm up period)
●Do not wire with the high voltage cable or the power lines.
Failure to do this will cause malfunction by induction or damage.
●Do not use the product in water.
●Operate within the rated range.
● Wipe off dirt on the emitting/receiving parts to maintain correct
detection. Also, avoid direct impact on the product.
CD33-30□□ CD33-120□□
CD33-50□□ CD33-250□□
CD33 SERIES
Displacement Sensor
● Confirm if the item meets your needs.
● Before the use, you should first thoroughly read this
manual and operate correctly as mentioned.
● You should keep this manual at hand for proper use.
Connection diagram
Laser type
Indicates a possible hazard that may result in death,
serious injury, WARNINGS or serious property damage
if the product is used without observing the stated
instructions.
● The light source of this product applies the visible light semiconductor
laser. Do not allow the laser beam to enter an eye, either directly or
reflected from reflective object. If the laser beam enters an eye, it may
cause blindness.
● Do not disassemble or modify the product since it is not designed to
automatically stop the laser emission when open. Disassembling or
modifying at customer's end it may cause personal injury, fire or electric
shock.
● This product is not an explosion proof construction. Do not use the
product under flammable , explosive gas or liquid environment.
● Use of controls or adjustments or performance of procedures other
Precautions for using laser
■Laser label
This product is classified as Class 2 (Ⅱ) Laser Product by JIS
C6802/IEC/FDA Laser Safety Standard.
●Regulations in the USA
When exporting laser devices to the USA, the USA laser control, FDA
(Food and Drug Administration) is applied. This product has been already
reported to CDRH (Center for Devices and Radiological Health). For
details, contact our customer service.
NPN type (Analogue/Voltage/Dual)
PNP type (Analogue/Voltage/Dual)
NPN type (RS422)
PNP type (RS422)
Pins configuration
*1 Defined with center strength 1/e2(13.5% ). There may be leak light other than the specified spot size.
The sensor may be damaged when there is a highly reflective object around the targets.
*2 Averaging: 64(High resolution), Sampling period:500μs, Object: white ceramic.
*3 Middle of measuring range, Object: white ceramic.
*4 Diameter of min bend cable is 40mm.
Installation
Caution for connection
1) Connect the lead wires correctly. The analog output wire must not be in contact
with any other wire. Do not turn on the power while wiring.
2) The blue wire(0V) and shield wire(analog GND) are internally connected.
Use the blue wire(0V) for the power supply and use the shield wire(analog GND) for
analog output.
Install the sensor and adjust the light spot onto the measuring point so that the distance indicator turns ON ( orange ) at
the middle of measuring range.
Use M4 screw (tightening torque need to be under 0.8N・m).
・Adjust the sensor position so that it is set parallel to the surface of object obtain reliable measurement (see above).
・If there is any foreign object around the spot that is glossier than the measuring object, it may cause incorrect
measurement.
Functions of components
Receiving part
Emitting part
Control panel
Fixture Hole
Fixture Hole
Distance indicator
Teach indicator
Run indicator
・Distance indicator
・Laser emission indication
(ON during laser emission)
Select button
Set button
MF indicator
Control output2
Control output1
Select Function
Into Teach mode:
function indicator
ex.)A type
・Control output stops during teaching and setting period while Analog output works.
Reset the presettings
Turn on the power by pressing Select button and Set button at the same time and keeping
them pushed continuously 5 seconds. Then make sure if all the indicator blinks 3 times to
confirm cancel of all presettings.
●Teach mode
●Special Setting mode
+
ex.)A type
optical axis
Surface of the object.
Distance indicator
shows orange when
object exists in the middle of
measuring range
(unit:mm)
Middle of
measuring
range
8.2
43.2
Carefully read and understand the safety precautions before operation. The
important information is provided to protect your health and property. Do
not apply any other installing or operating procedure other than that
Mandatory Requirements
Safety Precautions
Meanings of Safety Symbol
●This product cannot be used as a safety device to
protect human body.
MF (multi functional ) input
Avg indicator
LED lights up , if receiving RS422 command.
Label-A
Label-B Label-C
Label-C
Label-B
Label-A