15
Function Parameter
Settings/Options
Noise Filter
C29
0 = turn off noise lter
1 = 1 digital lter strength
2 = 2 digital lter strength
3 = 3 digital lter strength
Print Time and Date
C30
0 = yy.mm.dd
1 = mm.dd.yy
2 = dd.mm.yy
3 = yy.mm.dd
Analog Output Setting
C31
0 = 0 - 5V ouput
1 = 4 - 20mA output
Calibrate Current
C32
4 - 20mA current
Relay Output Setting
C33
0 = turn off relay output
1 = turn on relay output function 1
2 = turn on relay output function 2
3 = Reserved menu
Gravity of Calibration
Location
C36
9.7000 - 9.9999
Gravity of Destination
C37
9.7000 - 9.9999
Version No.
C38
Print Mode
C41
0 = auto mode
1 = gross mode
2 = tare mode
Print Carriage Return
C42
0 - 9 (How much space between print outs)
Space Print
C43
0 - 9 (Where the data prints on the paper: 0 = left ; 9 = right)
Date Print
C44
0 = do not print the date
1 = print the date
Time Print
C45
0 = do not print the time
1 = print the time
Baud Rade for
2nd RS232
C48
0 = 1200 (for remote display)
1 = 2400
2 = 4800
3 = 9600
Table 2. Unit Conversion Parameter Settings
Parameter Settings Units Available
C01= 3 & C12= 0 gram only
C01= 4 & C12= 0 oz only
C01= 1 & C12= 0 kg only
C01= 1 & C12= 1 kg/lb
C01= 1 & C12= 2 kg/lb/oz
C01= 1 & C12= 3 kg/lb/lb:oz/oz
C01= 1 & C12= 4 kg only
C01= 2 & C12= 0 lb only
C01= 2 & C12= 1 lb/kg
C01= 2 & C12= 2 kg/lb/oz
C01= 2 & C12= 3 kg/lb/lb:oz/oz
C01= 3 & C12= 4 lb only