21
4. If more thorough cleaning is required, follow below additional steps.
a. Drain the steam vessel of all pressure and water.
b. Remove high, com, low water probe sensors and safety valve from the vessel.
c. Unscrew 4 fixed bolts and detach all of support brackets from control box
d. Detach a flexible intake hose from the cylinder.
e. Loosen the band located at the bottom of the cylinders. Lift up to remove inner and outer
cylinders together.
f. Using a vacuum cleaner, clean both interior & exterior of the steam vessel.
g. If necessary, detach the steam vessel from the main chassis and wash with water. Let it dry
completely before reassembling.