  • V
    Vincent CaldwellAug 8, 2025
    Why do all stations not turn on my Orbit 57936 Timer?
    • J
      Jose BennettAug 8, 2025
      If all stations on your Orbit Timer aren't turning on, it could be due to several reasons. First, the transformer might be defective or not correctly connected. Second, the programming could be incorrect. Finally, ensure that the timer is not in OFF mode.
  • E
    Elizabeth WilsonAug 13, 2025
    What to do if my Orbit 57936 will not power up?
    • W
      William BurnsAug 13, 2025
      If your Orbit Timer won't power up, the issue could stem from a defective or incorrectly connected transformer. Also, check that the transformer is plugged into a working AC outlet and that the timer is fully seated on the docking port.
  • Z
    Zachary ReeseAug 20, 2025
    Why do stations turn on when they are not supposed to on my Orbit Timer?
    • P
      patricia45Aug 20, 2025
      If stations on your Orbit Timer are turning on when they shouldn't, it might be because the water pressure is too high. Also, check if more than one cycle is programmed or if stations are set to water with both programs.
  • A
    Amanda JacksonAug 26, 2025
    Why do stations continue to turn on and off when they are not programmed to on my Orbit Timer?
    • R
      Ronald MontoyaAug 26, 2025
      If stations on your Orbit Timer continue to turn on and off when they are not programmed to, it could be due to multiple cycles being programmed, excessive pressure, stations being set to water with both programs, or water budgeting being set to more than 100%.
  • D
    Dawn WalshSep 1, 2025
    What causes a persistent fault on my Orbit Timer?
    • S
      shellybrightSep 1, 2025
      A persistent fault on your Orbit Timer may be due to a short in the wiring or solenoids.

Summary

Introduction

Key Features and Capabilities

Overview of PC programmability, dual programs, stacking, docking port, remote control, and LCD.

Advanced Functionality

Explains multi-language support, water budgeting, and optional rain sensor integration.

Getting Started

Initial Setup Process

Guides on setting language, current time, date, and planning the watering schedule.

Programming Your Timer

Program and Station Settings

Covers program toggling, setting watering days, start times, and station durations.

Remote Control Device

Remote Operation Guide

Instructions for watering all or specific stations using the remote control.

Remote Synchronization

Steps to synchronize the remote control device with the timer for proper function.

Installation Guide

Location and Mounting

Criteria for selecting an installation location and mounting the docking port.

Electrical Connections

Instructions for connecting the transformer and sprinkler valve wires to the timer.

Remote Sleeve Installation

Steps for mounting the sleeve for the remote control device.

Diagnostics and Troubleshooting

Fault Detection and Notification

Explains Smart-Scan fault detection for solenoids, wiring, and pump/master valve faults.

Circuit Breaker and Fault Correction

Details the auto-resetting circuit breaker, causes for tripping, and steps to correct faults.

Common Troubleshooting Scenarios

Addresses issues like stations not turning on, unexpected cycling, or timer power failures.

Orbit 57936 Specifications

General IconGeneral
Delay WateringYes
Manual WateringYes
Number of Stations1
Power SourceBattery
Hose Connection Size3/4 inch
MaterialPlastic
Dimensions5.5 x 3.5 x 2.5 inches
Battery TypeAA (2)
ColorBlack
Watering Duration1 min to 4 hours

Related product manuals