T15M small stable light source instruction manual
Products introduction
Backlight control
Wavelength selection
Carrier output
Power-on and power-saving function settings
T15M stable light source, which is characterized by output
optical power, wavelength and spectrum.The width is stable
and the range of change is small. While the appearance is
upgraded, LED lighting is added.Provide 1310nm and 1550nm
dual-wavelength laser output, mainly used for FTTX
network.And fiber optic testing. When combined with an
optical power meter, it is used to measure optical power and
end End-to-end optical loss.
1
3
9
8
4
5
6
12
11
10
7
2
nm
1310
HZ
270
CW/HZ
KLS-25m Light Source
Auto-o�
OLS interface:
1
LED lighting
2
Display
3
Enter key
4
LED key
5
CW/HZ key
6
On/off key: turn on or off the device
7
Automatic shutdown
9
Frequency
10
Power supply battery
8
Unit
11
Wavelength
12
The equipment will turn on
after pressing the " " key. Press
this button again for more than
two seconds to shut down.
This instrument has power saving
function, normal there is no operation
for about ten minutes after booting,
The device will automatically shut down.
If you needa screen Shield this function
to keep the equipment working all the
time Status, just short press "on" when
booting Key, "Auto-off" at the bottom
left of the meter display. Disappearing
means that the power saving function
is cancelled.
nm
1310
HZ
270
CW/HZ
Auto-off
Auto-off
nm
1310
HZ
270
CW/HZ
Auto-o�
CW/HZ
In the power-on state, the backlight
will automatically turn off after a
period of time. After turning off, press
any key to activate the backlight. The
backlight is used to illuminate the
instrument display at night or in dark
places.
λ
1310
nm
1550
nm
nm
1310
HZ
270
CW/HZ
KLS-25m Light Source
Auto-o�
According to the needs of the project,
select the corresponding wavelength to
match the optical power meter. After the
meter is turned on, press the "output
wavelength" key, the output wavelength
and length will be switched to the
corresponding wavelength in turn, and
will be displayed on the display. The
laser light source of this series can
provide 1310nm and 1550nm
dual-wavelength laser output according
to demand.
nm
1310
HZ
270
CW/HZ
Auto-o�
CW/HZ
HZ
270
HZ
1000
HZ
2000
In the actual project, it is necessary to
load the audio carrier in the optical signal
to identify the optical fiber. The equip-
ment contains three carrier frequencies,
which are 270Hz, 1KHZ, and 2KHz. After
pressing the "modulated carrier" key, the
equipment will load different carriers in
sequence, and the display will be
displayed at the same time. The current
carrier frequency will be displayed on the
screen.