If the function of Tension is set to ON , a proof- test ( about 2N) of
the Splice point is performed automatically upon completion of
fusion splicing. Set the function of Tension in the following steps:
1. Use the or key to move the cursor to Tension ,
2. Use the
X - Y / -
or
ARC
/+
key to switch between different mode.
C.4
C.4
C.4
C.4 Power
Power
Power
Power Save
Save
Save
Save
T he splicer will be shut down certain duration of time (about 5
minute s) to save unnecessary loss of battery capacity, when it is set to
power saving mode. Use the or key to move the cursor to
Power Save , and then u se the
X - Y / -
or
ARC
/+
key to switch between
different mode.
C.5
C.5
C.5
C.5 Restore
Restore
Restore
Restore Factory
Factory
Factory
Factory Settings
Settings
Settings
Settings
W hen the instrument is produced, there are some parameter s( such as
Fiber Type, Para. Group, Heat Time and Fusion Mode) installed
R estoring factory settings is set by pressing the key twice,
when the cursor is move d to Restore Factory Settings . W hen the
instrument is restored factory settings, the parameter s of F iber Type is
SM, P ara . Group is 01, the Heat Time is 50s, the Fusion Mode is
Manual, the Tension is set to OFF , the Power Saving is ON. The
table C-1 below show s other default parameter s.