15
Operation Procedure
Pressure range during operation / How to Correct Vacuum Level
(
Gauge Pressure
)
/Stop
Pressure range during operation
kPa KRF70
110(Standard) KRF70(High-pressure)
Use as vacuum
pump
(V type)
Continuous
operative
vacuum
60 or lower 80 or lower
Use as blower
pump(B type)
Continuous
exhaust
pressure
60 or lower 70 or lower
Use as vacuum
pump and
blower pump
(V, B type)
Continuous
operative
pressure
Total of continuous operative
vacuum and continuous exhaust
pressure 60 or lower
Total of continuous operative
vacuum and continuous exhaust
pressure 80 or lower
1 Recommended range: The pump operating under 1 atmospheric pressure can exert its optimal
performance (life, operation noise, etc.) at a vacuum/pressure within this range.
Use the pump within the recommended range unless the higher vacuum/pressure is required.
Contact with Orion or Orion dealer for other usage.
How to Correct Vacuum Level (Gauge Pressure)
Correction formula: A = C (101.3 B)
A : Vacuum level at 1 atmosphere kpa
B : Atmospheric pressure at vacuum level measuring position kpa
C: Reading on compound gauge kpa
Ex) When the reading on the compound gauge is 76kPa and the atmospheric pressure is 973hPa
(97.3kPa), the vacuum level at 1 atmosphere is calculated as follow:76 + (101.3 – 97.3) = 80kPa
To read the accurate vacuum level, use a mercury manometer or an equivalent meter based on
absolute pressure.
Atmospheric pressure conversion formula (hPa kPa)
B(kPa)=B(hPa)÷10
Stop
Shut off the power switch.