6
Precautions for Proper Operation
■For inlet air, aim at normal temperature and normal
humidity clean air with little dust but free from
corrosive and explosive gases.
※Normal temperature: 0 to 40 deg. C
※Normal humidity: 65% +/- 20% (JIS Z 8703)
■Prohibition of operation in reverse rotation.
■Set the ambient temperature of the dry pump to the
range of 0 to 40 degrees C.
Try not to cause condensation inside the pump.
■Keep the pump away from oil, water, dust, rain, etc. Also, never lubricate the product.
■Be sure to use under specified pressure or less.
■Do not remove the main cover, and top and bottom partition plates. Removing these cover and plates
may result in shortening the life of product severely due to the temperature rise.
■Install the product on a flat surface..
■Periodically replace consumable parts (see pages 20) and replacement parts (see page 21).
■Be sure to Install the product on the level while whole base is touching on the level surface like in
figure A.
※do not Install the product like in figure B.
Fig.A
Fig.B
Cushion rubber etc