EasyManua.ls Logo

Orion MIS-4220 - 3. Protocol Example; 3.1 Send Command Examples; 3.2 Receive Command Examples

Orion MIS-4220
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50
MIS-4220 / MIS-4220R / MIS-4230
51
Infinitely Expandable
Protocol Example3.
3.1 Send Command
3.1.1 Multi Scale Control
Multi Scale Command
(PDP ID = 3, Source = PC, Configuration = 2x2)
Multi
Scale
(19byte)
Command PDP ID Sub Command
0x36 0x3B 0x34 0x3D 0x30 0x33 0x34 0x3D 0x37 0x33
Data
End
Source Width Height Position
0x37 0x30 0x30 0x32 0x30 0x32 0x30 0x33 0x0d
Index Converted Data Send Data
Command 0x36, 0x3B, 0x34, 0x3D
PDP ID "3": 0x30, 0x33 0x30, 0x33
Sub Command 0x34, 0x3D, 0x37, 0x33
Source PC(0x70): 0x37, 0x30 0x37, 0x30
Width "2": 0x32, 0x32 0x30, 0x32
Height "2": 0x32, 0x32 0x30, 0x32
Position
ID is "3", so position value
"3": 0x30, 0x33
0x30, 0x33
3.1.2 PDP Control
Power On Command (PDP ID = 1)
Power On
(11byte)
Command PDP ID Sub Command End
0x36 0x3B 0x34 0x3D 0x30 0x31 0x35 0x32 0x36 0x3E
0x0d
Index Converted Data Send Data
Command 0x36, 0x3B, 0x34, 0x3D
PDP ID "1": 0x30, 0x31 0x30, 0x31
Sub Command 0x35, 0x32, 0x36, 0x3E
3.1.3 Get Data Control
Get WhiteBalance Version Command(PDP ID = 1)
Get
White
Balance
(11byte)
Command PDP ID Sub Command End
0x36 0x3B 0x34 0x3D 0x30 0x31 0x34 0x37 0x35 0x34
0x0d
Index Converted Data Send Data
Command 0x36, 0x3B, 0x34, 0x3D
PDP ID "1": 0x30, 0x31 0x30, 0x31
Sub Command 0x34, 0x37, 0x35, 0x34
3.1.4 WhiteBalance Control
Graphic Data Brightness Command
(PDP ID = 1, Data = 50)
Graphic
Data
Brightness
(17byte)
Command PDP ID Sub Command
0x36 0x3B 0x34 0x3D 0x30 0x31 0x34 0x37 0x35 0x34
Data End
0x33 0x32 0x0d
Index Converted Data Send Data
Command
0x36, 0x3B, 0x34, 0x3D
PDP ID
"1": 0x30, 0x31 0x30, 0x31
Sub Command
0x34, 0x37, 0x36, 0x31
Data
"50"(0x32): 0x33, 0x32
0x33, 0x32
3.1.5 BIC Control
BIC Local Data Send Command (PDP ID = 1)
BIC
Local
Data
(17byte)
Command PDP ID Sub Command
0x36 0x3B 0x34 0x3D 0x30 0x31 0x34 0x32 0x35 0x3C
Data End
0x30 0x34 0x30 0x31 0x30 0x34 0x0d
Index Converted Data Send Data
Command 0x36, 0x3B, 0x34, 0x3D
PDP ID "1": 0x30, 0x31 0x30, 0x31
Sub Command 0x34, 0x32, 0x35, 0x3C
Data
0x30, 0x34, 0x30, 0x31,
0x30, 0x34
3.2 Receive Command
3.2.1BIC Control
BIC Local Data Receive Command (PDP ID = 1)
BIC
Local
Data
(25byte)
Command PDP ID Sub Command
0x36 0x3B 0x34 0x3E 0x30 0x31 0x34 0x32 0x35 0x3C
Data End
0x30 0x34 0x30 0x31 0x30 0x34 Receive 8 byte 0x0d
Index Converted Data Send Data
Command 0x36, 0x3B, 0x34, 0x3D
PDP ID "1": 0x30, 0x31 0x30, 0x31
Sub Command 0x34, 0x32, 0x35, 0x3C
Data
0x30, 0x34, 0x30, 0x31,
0x30, 0x34
󱱝
󱱝

id[0] = 0x30
id[1] = 0x31

id[0] = 0x30
id[1] = 0x32

id[0] = 0x30
id[1] = 0x33

id[0] = 0x30
id[1] = 0x34

id[0] = 0x30
id[1] = 0x35

id[0] = 0x30
id[1] = 0x36

id[0] = 0x30
id[1] = 0x37

id[0] = 0x30
id[1] = 0x38

id[0] = 0x30
id[1] = 0x39

id[0] = 0x30
id[1] = 0x3A

id[0] = 0x30
id[1] = 0x3B

id[0] = 0x30
id[1] = 0x3C

id[0] = 0x30
id[1] = 0x3D

id[0] = 0x30
id[1] = 0x3E

id[0] = 0x30
id[1] = 0x3F

id[0] = 0x31
id[1] = 0x30

id[0] = 0x31
id[1] = 0x31

id[0] = 0x31
id[1] = 0x32

id[0] = 0x31
id[1] = 0x33

id[0] = 0x31
id[1] = 0x34

id[0]=0x31
id[1]=0x35

id[0]=0x31
id[1]=0x36

id[0]=0x31
id[1]=0x37

id[0]=0x31
id[1]=0x38

id[0]=0x31
id[1]=0x39

Downloaded From TV-Manual.com Manuals