EasyManuals Logo

Oromed ORO-N4 CLASSIC User Manual

Oromed ORO-N4 CLASSIC
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
– 1 –

Wprowadzenie i przeznaczenie ................................................................... 4
Uwaga ................................................................................................................. 4
Ważne informacje dotyczące ciśnienia krwi i jego pomiaru ................. 7
Części składowe ciśnieniomierza ..............................................................10
Cechy modelu ORO-N4 CLASSIC ............................................................ 11
Pierwsze użycie ciśnieniomierza ...............................................................11
Wykonywanie pomiaru ................................................................................13
Czujnik nieregularnego rytmu serca .........................................................18
Korzystanie z zasilacza sieciowego ........................................................... 23
Specyfikacja techniczna...............................................................................25
Wymagane warunki pracy ..........................................................................26
Warunki przechowywania i transportu ..................................................26
Klasyfikacja .....................................................................................................26
Deklaracja EMC .............................................................................................27

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oromed ORO-N4 CLASSIC and is the answer not in the manual?

Oromed ORO-N4 CLASSIC Specifications

General IconGeneral
Display:65mm x48mm LCD Digital Display
Cuff pressure display range:0–299 mmHg
Accessories:1×Main Device, 1×Cuff, 1×Users manual, 1×Warranty card, Wide range rigid cuff 8.7” – 18.1” (22 - 36 cm)
Users:Adult
Operating Conditions:Temperature: 5° to 40°; Humidity: 15% to 93% RH;
Storage And Shipping Conditions:Temperature: -25° to 70°; Humidity: 10% to 93% RH; Pressure altitude: 70KPa~106Kpa
Pressure altitude:70KPa~106Kpa
Measuring method:Oscillometric
Measuring range:0-280 mmHg
Pulse:40 to 199 per minute
Measuring resolution:1 mmHg
Accuracy:Pressure within ± 3 mmHg / pulse ± 5 % of the reading
Pressure sensor:Capacitive
Memory:Last 120 user (total 240)
Power source:a) 4 AAA batteries, 1.5 V b) AC adapter 6 V DC 600 mA (voltage 4.5 V DC to 6 V DC) (Optional)
Automatically power off:1 minute
Weight and Dimensions IconWeight and Dimensions
Wight:225.5g(batteries and AC adapter is not included)
Size:118 (W) x 110 (L) x 52(H) mm