MICROmatic
MINImatic
MIDImatic
MULTImatic
SISTEMI DI RIFASAMENTO AUTOMATICI
MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE
AUTOMATIC POWER FACTOR CORRECTION SYSTEMS
INSTALLATION, OPERATING AND MAINTENANCE MANUAL
SYSTEMES DE COMPENSATION DE LENERGIE REACTIVE
MANUEL DINSTALLATION, UTILISATION ET ENTRETIEN
MAT 189 june 2019

Table of Contents

Questions and Answers

  • P
    Paul RandallAug 5, 2025
    What to do if the ORTEA NEXT ICAR MICROmatic HP10 Transformer controller fails to switch on?
    • W
      William ClarkAug 5, 2025
      If the ORTEA NEXT Transformer controller fails to switch on, and all LEDs or the display are off, it could be due to several reasons: * The disconnect switch might not be on. In this case, turn the disconnect switch on. * The control circuit fuses may have blown. Identify what caused the fuses to blow and then replace them. * The quick connect terminal boards inside the unit might be disconnected. Ensure they are correctly engaged on the controller. * The controller itself might be faulty. Check the controller's power supplies, and if they are working correctly, replace the controller with an original spare one.
  • B
    Brandon DavidAug 11, 2025
    Why does my ORTEA NEXT Transformer controller display an unreal power factor?
    • A
      Anna HaneyAug 11, 2025
      If the ORTEA NEXT Transformer controller displays an unreal power factor, it could be due to: * The current transformer being enabled on the incorrect phase. To resolve this, position the current transformer on phase L1 (R) referred to the cabinet. * A faulty current transformer. If this is the case, replace it with a suitable one. * A faulty controller. In this instance, replace it with an original spare one.
  • J
    John BurnsAug 17, 2025
    What to do if ORTEA NEXT ICAR MICROmatic HP10 controller fails to switch in the capacitor banks?
    • J
      Jodi NguyenAug 17, 2025
      If the ORTEA NEXT Transformer controller fails to switch in the capacitor banks, check the following: 1. Ensure the current transformer is correctly positioned upstream of all loads and the power factor correction system. If it's only upstream of the power factor correction system, reposition it. 2. Verify the current transformer is on phase L1 (R) referred to the unit. If it's on the incorrect phase, correct its position. 3. Confirm the controller is in automatic mode. If it's in manual mode, switch it to automatic. 4. Assess the current transformer amperage. If it's lower than the sensitivity threshold, increase the load current or use a current transformer with a suitable primary ratio.
  • G
    Gary NelsonAug 22, 2025
    Why ORTEA NEXT Transformer controller switches in all the capacitor banks without increasing the power factor?
    • X
      xwhitakerAug 22, 2025
      If the ORTEA NEXT Transformer controller switches in all the capacitor banks without increasing the power factor on the display, it might be caused by: * The current transformer being installed at an incorrect point in the system, only upstream of the load but downstream of the power factor correction system. To fix this, correctly position the current transformer upstream of all the loads and the power factor correction system. * The current transformer being enabled on the incorrect phase. If so, position the current transformer on phase L1 (R) referred to the unit.
  • J
    Jessica PenaAug 29, 2025
    How to fix ORTEA NEXT ICAR MICROmatic HP10 Transformer controller that switches capacitor banks in and out continually?
    • M
      Michael MorrisonAug 29, 2025
      If the ORTEA NEXT Transformer controller switches the capacitor banks in and out continually without finding a balance, it is likely due to a faulty setting of the controller parameters. To resolve this, check the current parameters and set them correctly.

Summary

EU Declaration of Conformity

Introduction

Information Property

Details copyright and rights reserved by the manufacturer.

Reference Normative

Lists directives and standards the units are designed and built in compliance with.

Definitions

Explains warning symbols like DANGER and NOTE used in the manual.

Proper Use

Outlines correct procedures and precautions for safe and effective equipment operation.

Misuse

Defines operations contrary to correct use and safety guidelines.

Environmental Notes

Health & Safety

Notes for the Operator

Essential safety guidelines and precautions for personnel operating the unit.

Notes for Maintenance

Critical safety instructions for maintenance personnel before and during work.

Behaviour

Guidelines on personnel conduct, correct and incorrect behaviour for safe operation.

Personal Protective Equipment (PPE)

Lists required PPE for safe interaction with the unit and its components.

Handling

Packaging

Describes the packaging methods and contents for unit delivery.

Reception

Instructions for checking unit integrity upon delivery and before installation.

Storage

Recommendations for storing the unit in suitable environmental conditions.

Moving the Unit

Safety precautions and methods for safely moving the unit during installation.

General

Installation and Commissioning

Site Choice

Requirements for selecting an appropriate installation location for the unit.

Ambient Temperature

Specifies the acceptable ambient temperature range for optimal unit operation.

Atmospheric Conditions

Conditions to avoid for installation, such as corrosive or dusty environments.

Assembly

Recommendations for fastening the units and specific mounting types.

Electrical Connection

Detailed instructions for safe and correct electrical wiring, including ground and CT connections.

Commissioning and Start-up

Steps for putting the unit into operation after installation and initial checks.

Incorrect Use

Explains improper operational modes that can lead to hazardous situations.

Reactive Power Controller

Maintenance

Safety Recommendations

Lists prohibited actions and general safety precautions during maintenance.

Routine Maintenance

Procedures and checks for regular, scheduled maintenance activities.

Special Maintenance

Guidelines for maintenance required due to unusual phenomena or operating conditions.

Replacement of Components

Procedures for replacing fuses, contactors, and capacitors when faulty.

Trouble Shooting During Installation

Allegato; Annex; Annexe A

Allegato; Annex; Annexe B

Allegato; Annex; Annexe C

Allegato; Annex; Annexe D

Allegato; Annex; Annexe E

Maintenance Record

ORTEA NEXT ICAR MICROmatic HP10 Series Specifications

General IconGeneral
Frequency50/60 Hz
Efficiency>98%
TypeVoltage Stabilizer
CoolingNatural Air Cooling