MICROmatic
MINImatic
MIDImatic
MULTImatic
SISTEMI DI RIFASAMENTO AUTOMATICI
MANUALE DI INSTALLAZIONE, USO E MANUTENZIONE
AUTOMATIC POWER FACTOR CORRECTION SYSTEMS
INSTALLATION, OPERATING AND MAINTENANCE MANUAL
SYSTEMES DE COMPENSATION DE LENERGIE REACTIVE
MANUEL DINSTALLATION, UTILISATION ET ENTRETIEN
MAT 189 june 2019

Table of Contents

Questions and Answers

  • D
    Dr. Joseph SweeneyAug 9, 2025
    What to do if the ORTEA NEXT ICAR MICROmatic HP20 controller fails to switch on?
    • M
      Maria SummersAug 9, 2025
      If the ORTEA NEXT Transformer controller fails to switch on, and all LEDs or the display are off, it could be due to several reasons: * The disconnect switch might not be on. In this case, turn the disconnect switch on. * The control circuit fuses may have blown. Identify what caused the fuses to blow and then replace them. * The quick connect terminal boards inside the unit might be disconnected. Ensure they are correctly engaged on the controller. * The controller itself might be faulty. Check the controller's power supplies, and if they are working correctly, replace the controller with an original spare one.
  • J
    jameshowardAug 15, 2025
    Why does my ORTEA NEXT Transformer controller display an unreal power factor?
    • O
      osawyerAug 15, 2025
      If the ORTEA NEXT Transformer controller displays an unreal power factor, it could be due to: * The current transformer being enabled on the incorrect phase. To resolve this, position the current transformer on phase L1 (R) referred to the cabinet. * A faulty current transformer. If this is the case, replace it with a suitable one. * A faulty controller. In this instance, replace it with an original spare one.
  • D
    dhunterAug 21, 2025
    What to do if ORTEA NEXT Transformer controller fails to switch in the capacitor banks?
    • R
      Ronald SwansonAug 21, 2025
      If the ORTEA NEXT Transformer controller fails to switch in the capacitor banks, check the following: 1. Ensure the current transformer is correctly positioned upstream of all loads and the power factor correction system. If it's only upstream of the power factor correction system, reposition it. 2. Verify the current transformer is on phase L1 (R) referred to the unit. If it's on the incorrect phase, correct its position. 3. Confirm the controller is in automatic mode. If it's in manual mode, switch it to automatic. 4. Assess the current transformer amperage. If it's lower than the sensitivity threshold, increase the load current or use a current transformer with a suitable primary ratio.
  • T
    thomas97Aug 27, 2025
    Why ORTEA NEXT ICAR MICROmatic HP20 Transformer controller switches in all the capacitor banks without increasing the power factor?
    • G
      Gina PenaAug 27, 2025
      If the ORTEA NEXT Transformer controller switches in all the capacitor banks without increasing the power factor on the display, it might be caused by: * The current transformer being installed at an incorrect point in the system, only upstream of the load but downstream of the power factor correction system. To fix this, correctly position the current transformer upstream of all the loads and the power factor correction system. * The current transformer being enabled on the incorrect phase. If so, position the current transformer on phase L1 (R) referred to the unit.
  • P
    Peter BatesSep 1, 2025
    How to fix ORTEA NEXT ICAR MICROmatic HP20 Transformer controller that switches capacitor banks in and out continually?
    • V
      Victor DuncanSep 2, 2025
      If the ORTEA NEXT Transformer controller switches the capacitor banks in and out continually without finding a balance, it is likely due to a faulty setting of the controller parameters. To resolve this, check the current parameters and set them correctly.

Summary

Introduction to the Manual

Guidelines for Proper Unit Usage

Outlines correct operation and safety procedures for the user.

Prohibited Operations and Misuse

Defines operations considered misuse and manufacturer disclaimers.

Health and Safety Precautions

Operator Safety Guidelines

Essential safety instructions for unit operators.

Maintenance Safety Procedures

Critical safety instructions for maintenance personnel.

Personal Protective Equipment (PPE) Requirements

Installation and Commissioning

Electrical Connection Procedures

Ground Connection Instructions

Details on proper earth wire connection.

Main Power Supply Connection

Instructions for connecting to the main power grid.

Current Transformer (CT) Connection

Guidance on connecting the current transformer.

Commissioning and Start-up

Incorrect Use Scenarios

Unit Maintenance Guidelines

Maintenance Safety Recommendations

Prohibitions and safety advice for maintenance tasks.

Troubleshooting During Installation

Annex B: Connection Diagrams

Annex E: Connection Cable Cross-Sections

ORTEA NEXT ICAR MICROmatic HP20 Series Specifications

General IconGeneral
BrandORTEA NEXT
ModelICAR MICROmatic HP20 Series
CategoryTransformer
LanguageEnglish