32GB
QUICK GUIDE
FINE SEARCH
Three transmitters are displayed; the
nearest transmitter is 10m away.
Direction: straight ahead!
FINE SEARCH
Fine search starts automatically when
you are 2m away. The direction arrow
is switched off. The tendency indica-
tor (= semicircle shaped segments)
formulates the fine search process
simply, quickly and precisely. The
searcher is approaching the victim:
the tendency indicator points to the
centre of the display. The closer you
are to the victim, the faster and louder
the acoustic signal beeps.
The searcher is now going away from
the victim. The semicircles get small-
er and the distance indicator number
will get larger.
The victim has been located. Burial
depth: 0.1m. No smaller numbers
and no stronger tendency indicator
appear.