Installation and Operation Manual - 1700
ENGLISH
2. General Information
2.1 Performances
Values are as measured per test method, except for the recommended heating area, firebox volume,
maximum burn time and maximum heat output.
Model OSBURN 1700 (OB01700)
Fuel Type Dry Cordwood
Combustion Technology Non-Catalytic
Recommended heating area (sq. ft.
.
)
1
500 to 1,800 ft
2
(46 to 167 m
2
)
Nominal firebox volume 1.9 ft
3
(0.054 m
3
)
Maximum burn time
1
6 hours
Maximum heat output (dry cordwood)
2
65,000 BTU/h (19 kW)
Overall heat output rate (min. to max.)
2 3
15,650 BTU/h to 23,300 BTU/h
(4.6 kW to 6.83 kW)
Average overall efficiency
3
Dry cordwood
70 % (HHV)
4
75 % (LHV)
5
Optimum efficiency
6
78 %
Average particulate emissions rate
7
1.26 g/h (EPA / CSA B415.1-10)
8
Average CO
9
58 g/h
1
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type
and other variables. The recommended heated area for a given appliance is dened by the manufacturer as its capacity to maintain a minimum
acceptable temperature in the designated area in case of a power failure.
2
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft
3
and 20 lb/ft
3
. Other performances are based on
a fuel load prescribed by the standard. The specied loading density varies between 7 lb/ft³ and 12 lb/ft
3
. The moisture content is between 19%
and 25%.
3
As measured per CSA B415.1-10 stack loss method.
4
Higher Heating Value of the fuel.
5
Lower Heating Value of the fuel.
6
Optimum overall efciency at a specic burn rate (LHV).
7
This appliance is ofcially tested and certied by an independent agency.
8
Tested and certied in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and draft ASTM WK47329-14 based on the ATM send
by EPA on October 12th, 2017.
9
Carbon monoxide.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Osburn 1700 and is the answer not in the manual?

Osburn 1700 Specifications

General IconGeneral
Heating Capacity500 - 1, 800 sq. ft.
Maximum Output65, 000 BTU/h
Chimney Diameter6 inches
EPA CertifiedYes
Firebox MaterialSteel
Maximum Log Length18 inches
Efficiency77% (LHV)