PRODUCT INFORMATION
PULL-FORCE MEASUREMENT SYSTEM POWER-CHECK 2
HSK with"V" groove
Adjust Power-Check 2 in 0-position and hold
it continual
Thread on adapter until in just bottoms out
(zero torque); M
A
= 0 Nm
(Counter screw must not come in contact
with Power Check)
tighten counter screw
SK with "V" groove
Adjust Power-Check 2 in 0-position and hold it continual
Thread on adapter until in just bottoms out (zero torque); M
A
= 0 Nm
(Counter screw must not come in contact with Power Check)
tighten counter screw
4 START-UP
The Power-Check 2 is a precision instrument Please handle with care!
Measuring conditions: the following requirements must definitely be fulfilled in order to
get accurate measurements
Measuring range (see technical data)
Temperature range (see technical data)
use suitable adapter, observe the proper steep taper standard!
The pull force measurement system is not protected against spray water if the base
unit is used in conjunction with a OTT-JAKOB adapter for manual operation.
Measurements not allowed if overpressure from the spindel side accumulate (such as
purge air)
The pull force measurement system is protected against spray water if the base unit is
used in conjunction with a OTT-JAKOB adapter with gripper groove.
POWER-CHECK-2_PE_2015-09
Subject to modification due to technical advance! // 16
!#
0
1