0
50
100
150
200
225
OILED AIR
COMPRESSOR
24L 2.0HP
INSTRUCTION MANUAL
SPECIFICATIONS
Power supply: 220–240V ~ 50Hz
Motor: 1500W (S2 15min), 2.0HP
Tank Capacity: 24L
No Load Speed: 2,850/min
Max. Pressure: 8bar (116psi)
Max. Flow Rate: 165L/min
Free Air Delivery: 54.4L/min
IP Rating: IP20
Weight: 22kg
ACP-2420
STANDARD EQUIPMENT
IN ORDER TO MAKE A CLAIM UNDER THIS
WARRANTY YOU MUST RETURN THE PRODUCT
TO YOUR NEAREST BUNNINGS WAREHOUSE WITH
YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO
RETURNING YOUR PRODUCT FOR WARRANTY
PLEASE TELEPHONE OUR CUSTOMER SERVICE
HELPLINE:
Australia 1800 069 486
New Zealand 0508 069 486
3 YEAR REPLACEMENT WARRANTY
Your product is guaranteed for a period of 36 months from
the original date of purchase. If a product is defective it will
be replaced in accordance with the terms of this warranty.
Warranty excludes consumable parts, for example: valve adapters
and accessories.
WARNING
The following actions will result in the warranty being void.
If the tool has been operated on a supply voltage other
than that specified on the tool.
If the tool shows signs of damage or defects caused
by or resulting from abuse, accidents or alterations.
Failure to perform maintenance as set out within the
instruction manual.
If the tool is disassembled or tampered with in any way.
Professional, industrial or high frequency use.
WARRANTY
TO ENSURE A SPEEDY RESPONSE PLEASE
HAVE THE MODEL NUMBER AND DATE OF
PURCHASE AVAILABLE. A CUSTOMER SERVICE
REPRESENTATIVE WILL TAKE YOUR CALL
AND ANSWER ANY QUESTIONS YOU MAY
HAVE RELATING TO THE WARRANTY POLICY
OR PROCEDURE.
OZITO
Australia/New Zealand (Head Office) 1-23 Letcon Drive, Bangholme, Victoria, Australia 3175.
The benefits provided under this warranty are in addition
to other rights and remedies which are available to you at law.
Our goods come with guarantees that cannot be excluded
at law. You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably foreseeable
loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.
Generally you will be responsible for all costs associated with
a claim under this warranty, however, where you have suffered
any additional direct loss as a result of a defective product you
may be able to claim such expenses by contacting our customer
service helpline above.
ozito.com.au
1118
Air Compressor
0
50
100
150
200
225

Questions and Answers

  • X
    xpayneAug 3, 2025
    What to do if my Ozito ACP-2420 does not start and the motor is overheated?
    • A
      Alejandro SheltonAug 4, 2025
      If your Ozito Air Compressor motor is overheated, allow it to cool down. If necessary, identify and fix the cause of the overheating. Also, if the compressor is overloaded, allow it to cool down before pressing the Overload Reset Switch and restarting the motor.
  • R
    Roberta JohnsonAug 9, 2025
    Why my Ozito Air Compressor does not start?
    • C
      cookpeterAug 9, 2025
      If your Ozito Air Compressor does not start, first check the power supply, the power plug and the socket-outlet to ensure they are working correctly. If the supply power is insufficient, reduce the length of any extension lead you are using.
  • T
    taylor11Aug 16, 2025
    What to do if my Ozito Air Compressor starts but there is no pressure to the air tool?
    • M
      Michael DelacruzAug 16, 2025
      If your Ozito Air Compressor starts, but no pressure is delivered to the air tool, check the compressed air hose and tools for loose connections or damage, and replace if necessary. Also, inspect the quick-lock coupling for leaks and replace if needed. Finally, ensure that the pressure regulator is set to a sufficient pressure by opening it further.
  • W
    williamspaulaAug 21, 2025
    Why won't my Ozito ACP-2420 start in cold weather?
    • T
      teresa49Aug 21, 2025
      If your Ozito Air Compressor does not start, it may be because the outside temperature is too low. Never operate the compressor when the outside temperature is below 5 degrees Celsius.
  • I
    Isabella BlackburnAug 27, 2025
    What to do if my Ozito Air Compressor starts but there is no pressure?
    • L
      lindsay25Aug 27, 2025
      If your Ozito Air Compressor starts but isn't building pressure, ensure the drainage valve is properly closed. If the seals are damaged, have them replaced by a service center.

Summary

WARRANTY

Warranty Claim Procedure

Instructions for making a warranty claim, requiring product return and receipt.

3 Year Replacement Warranty

Details the 36-month guarantee period and replacement terms for product defects.

Warranty Voiding Conditions

Lists actions that will invalidate the product warranty, such as misuse or improper maintenance.

SETUP & PREPARATION

OPERATION

USAGE

TROUBLESHOOTING

Compressor Not Starting

Identifies common causes and solutions for the compressor failing to start.

Pressure Issues

Addresses problems with the compressor building pressure or delivering it to the tool.

Ozito ACP-2420 Specifications

General IconGeneral
ModelACP-2420
Max Pressure800kPa / 116psi
Tank Capacity24L
Power1.5kW (2.0HP)
Voltage230-240V ~ 50Hz
MotorInduction Motor
No Load Speed2850 RPM
Noise Level97 dB