21
Attention: If any wrong installation or use is found during the service under product warranty, a
service fee is charged.
10. Appliance does not drain;
Check and clean the filters.
Check if drain hose and drain vent are not clogged.
In appliances with a motorized drain unit, drain system should comply with section 4.6.
11. Water intake is slow;
Check if water supply taps are open.
Check water pressure. It should be 2-4 bars. If pressure is low, fit a booster pump.
Clean water outlet parts on the rinsing arms.
Check if water hose is clogged or bent.
If low pressure is due to the pressure reducer on the water supply line, regulator can be removed.
CAUTION
The building, facility or area where the appliance is to be installed should have a proper electrical installation
as per the interior wiring regulation, and all measures for life and property safety should be taken.
OTHERWISE, OUR COMPANY WILL NOT ACCEPT ANY LIABILITY.