° Fill in the tank through the load pipe union with drinkable water
° Close again the outside load pipe union
Draining
° Open the exhaust faucet (pict.34)
°Open the security valve for the draining of the boiler following the specic instructions (pict.35).
° Open the faucets of the kitchen- and Wc washbasins.
° Activate the water pump through the switch on the control panel of the junction box.
Pict. 34 – unload valve Pict. 35 – boiler draining valve
Remember to refer to the indications about homologated total weight for your vehicle, calculating
that the weight of the water in the tank contributes to the determination of that value. Asa a
consequence, in establishing the useful weight, it is compulsory to consider the necessity to ll
I the water tank.
If the tank is full and the pump works, but no water comes out from the faucets, the lter could
be dirty or clogged. In this case clean the lter (if it is external).
If the pump works in vain it can be damaged.
Cleaning of the external lter(pict.36)
°Disconnect from the control panel the 12V supply of the pump.
° Empty the tank and all tubing of the system
° Unscrew the plastic joint that binds the lter with the unload tube.
° Unscrew the transparent cover of the lter and extract the lter body.
° Clean the lter with water and a brush.
Pict. 35 - pump with outside lter