13
Baery-/Energymonitor
Terminals5,7,9and10havebaerymonitors
topreventdeepdischargewhichwilldamage
thebaeries(alsofrostprotecon).Terminal
10areshutoat22.5V(MaxiXL19V),while
othersareshutoat21V.Allterminalopen
again when charging commences and the
voltageexceeds23.5V.
Terminal 10 also have energy monitors =
If P-LIGHT® is inacve for 96 hours, the
terminal are closed and they open again
when the parking lightscome on again via
P-LIGHT®(pushbuon1)orthetruck.
Programmable switching
Alternave1
Midi:Jumperbetweenterminals23&24for
atleast20seconds.
Maxi: Hold down pushbuon 2 (the top
one)foratleast20seconds.Amessagethen
appearsinthedisplay,ifyouwanttochange,
repeattheprocedure.
AUT ON = ALWAYS switches on P-LIGHT®
outputs5and7whenthetruckisswitched
oordisconnected.
AUT OFF = NEVER switches on P-LIGHT®
outputs5and7whenthetruckisswitched
o or disconnected (Factory seng on
delivery)
Alternave2
Executethesequence“o-on-o-on”within
10 seconds with the truck’s lighng to
automacally acvate terminals 5 and 7 if
youdisconnect/switchothetruckwithin2
minutes.
Thisalternavemeansthatyoucanalways
makeyourowndecisiononwhenP-LIGHT®
shouldbeswitchedon.
Reseable circuit breaker funcon
If any of the circuit breakers trip, this is
shownonthedisplay(ontheelectronicsbox)
byanalternangmessageof“Err”and“Fx,
where“x”isthetrippedfuseID.Ifthetruckis
disconnected,thefusefaultisonlydisplayed
for30secondsaerpressingthebuon,to
save the baery. If the truck is connected,
themessageisdisplayedconnuously.
NOTE:Ifareseablecircuitbreakertrips,the
supplymustbedisconnected(for15-60sec)
inorderforthebreakertoreset.Ifthetrip-
outhasbeencausedbyashort-circuitbulb,
thismustalsobereced.
Terminal 5, 7, 9 and 10 have built-in
automac fuses, total simultaneous max.
take-os Midi = max 100W / Maxi = max
270W.
If, for some reason it is necessary to bypass
the P-LIGHT® electronics box, the wires
between “4” and “5”, and “6” and “7” must
be connected together.