FACE SHIELD REPLACEMENT
*The face shield is an optional accessory. In case your conguration includes a face
shield and if it needs to be replaced, please follow the following instructions:
Picture 30
1
2
3
4
5
1
Using a cross-tip screwdriver loosen the 2 screws on the inner sides of the shell
(see Picture 31).
2
Carefully disassemble all the parts: screw (1), inner plastic protector (2), gasket
(3), side covers (4), lamp holder adapters (5), and remove the old face shield from
its position.
3
Place the new face shield on the side holes and carefully reassemble all the
parts: screw (1), inner plastic protector (2), gasket (3), side covers (4) and lamp
holder adapters (5), to their original positions. Secure the visor and all the parts
with a crosstip screwdriver.
4
Before wearing the helmet, check if the face shield is properly xed – the face
shield should slide smoothly between standby and use positions.
For more information, please check regularly our website www.pab.hr or contact