- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - INSTRUCTION MANUAL
3601 E. 34th St. Tucson, AZ 85713 USA Tel. +1 520-882-6598 Fax +1 520-882-6599 email: pace@metallographic.com Web: http://www.metallographic.com
Please read this instruction manual carefully and follow all installation, operating and safety guidelines.
NANO 2000T Polisher
Programming Step Value Description
SR 1.4
Belt ratio - DO NOT CHANGE
(Enter PW 0253 to access)
SP1 SPEED Disc Speed - VARIABLE
T1 TIME Runtime for SP1
SP2 to SP8 200 Multiple step disk speed - DO NOT CHANGE
T2 to T8 0 Runtime for multiple steps - DO NOT CHANGE
CN 1 Number of cycles – DO NOT CHANGE
SL 100 Disc speed for SPL - preset to 100 rpm
SN 200 Disc speed for SPM - preset to 200 rpm
SH 300 Disc speed for SPH - preset to 300 rpm
DF Defaults—DO NOT CHANGE
U SET 110/220V—DO NOT CHANGE
ST 65 Shutoff motor temperature - DO NOT CHANGE
CT Current motor temperature - DO NOT CHANGE
CD1 0 Controlled by RUN/STOP button - DO NOT CHANGE
CD2 10 Display speed - DO NOT CHANGE
NANO 1000T/2000T and 1200T with 20 rpm increments (1 and 1.5 hp motor)