EasyManua.ls Logo

Pacific Sun Kore 7th - User Manual

Pacific Sun Kore 7th
79 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Kore 7th
Ultimate dosing station
User Manual
ver. 3.0
Android interface
www.Pacific-Sun.eu

Table of Contents

Other manuals for Pacific Sun Kore 7th

Questions and Answers

  • M
    Mary WiseAug 1, 2025
    How to improve the accuracy of Pacific Sun Laboratory Equipment?
    • C
      Charles CurtisAug 1, 2025
      To improve the accuracy of your Pacific Sun Laboratory Equipment, ensure the following: * Pump #1 and pump #2 are correctly calibrated and free of long air gaps in the silicone tubing. Note that small air bubbles are acceptable. * The magnetic stirring bar/pellet is inside the kHLab cylindrical test chamber, as instructed. * Silicone tubing supplying reagent and test water are fully submerged below the liquid levels. * The green tip under the kHLab module chamber cover remains submerged during alkalinity tests. If you've recently replaced the dosing pumps PharMed tubing, allow a few days for the device to stabilize before recalibrating, unless the new tubing has a different diameter or nominal flow than the original Pacific Sun tubing.
  • D
    dochoaAug 5, 2025
    What to do if Pacific Sun Laboratory Equipment alkalinity results vary widely?
    • D
      Devin CampbellAug 5, 2025
      If you are experiencing widely varying measured alkalinity results with your Pacific Sun Laboratory Equipment, the pump heads rollers might be dirty. Check the pump heads rollers for any black buildup, dust, or lubricant/grease. If the rollers are dirty, remove the dosing pump head and clean the rollers using a fresh paper towel and alcohol or a different solvent solution.
  • K
    Kathleen FarmerAug 9, 2025
    Why is the magnetic stirrer bar/pellet not spinning in my Pacific Sun Laboratory Equipment?
    • M
      Maurice SmithAug 10, 2025
      If the water mixing magnetic stirrer bar/pellet in your Pacific Sun Laboratory Equipment is not spinning, increase the “Stirrer speed” in the Cloud Application under the "KH Lab Settings". The default is 100, try increasing it to 150 or higher. If the water mixing magnetic stirrer bar/pellet is spinning too fast, decrease the “Stirrer speed”.
  • M
    Mr. Joseph Miller Jr.Aug 18, 2025
    What to do if Pacific Sun Kore 7th Measuring Instruments alkalinity results vary widely?
    • A
      alexandriabernardAug 18, 2025
      If you're experiencing inconsistent alkalinity readings with your Pacific Sun Measuring Instruments, the pump heads rollers might be dirty. Check for any black buildup, dust, or lubricant/grease on the rollers. If they're dirty, remove the dosing pump head and clean the rollers thoroughly.
  • R
    Roger MartinAug 22, 2025
    Why is magnetic stirrer bar not spinning in Pacific Sun Measuring Instruments?
    • A
      Angela BaileyAug 22, 2025
      If the magnetic stirrer bar/pellet isn't spinning in your Pacific Sun Measuring Instruments, try these adjustments: * In the application, under the “kHLab” tab, increase the “Stirrer speed” from the default 100 to, for example, 150 or higher. Save the setting by clicking "Save speed" and test again. * If increasing the speed doesn't help, try decreasing the “Stirrer speed”, save it by clicking "Save speed" and test again.
  • S
    Samuel JohnsonAug 27, 2025
    What to do if Pacific Sun Kore 7th dosing station won't connect to PC?
    • D
      deborah02Aug 27, 2025
      To resolve communication issues between your Pacific Sun Measuring Instruments dosing station and the application on your PC, verify that the correct communication COM port number is selected in the application. Note that connecting a mobile device to Kore 7th will block Internet access on your mobile device through the Wi-Fi network; communication will only occur between the mobile device and Kore 7th.
  • K
    Kevin AlvarezNov 13, 2025
    How to fix inaccurate readings on Pacific Sun Kore 7th Measuring Instruments?
    • J
      Jo GrossNov 13, 2025
      If your Pacific Sun Measuring Instruments device isn't providing accurate readings, ensure the following: * Pump #1 and pump #2 are correctly calibrated and free of long air gaps in the silicone tubing. Note that small air bubbles don't affect accuracy. * The magnetic stirring bar/pellet is correctly placed inside the kHLab cylindrical test chamber, following the instructions. * Silicone tubing supplying reagent and test water are fully submerged below the surface of the reagent solution and aquarium water. * The green tip under the kHLab module chamber cover remains submerged during alkalinity tests. When you replace dosing pumps with PharMed tubing, the device's performance might change slightly at first, but it should return to its usual accuracy within a few days. Avoid recal...

Summary

Introduction and Device Overview

Product Information and Features

Overview of the Kore 7th and kHLab's purpose, capabilities, and package contents.

Technical Specifications

Outlines technical specifications for the kHLab module, including accuracy, modes, and dimensions.

Device Installation and Network Setup

Physical Installation and Connections

Guidance on device placement, ports, tubing, and cable connections.

Wi-Fi and Remote Connectivity

Steps for Wi-Fi setup, home network connection, IP forwarding, and Virtual Serial Port.

Application Installation

Windows Application Installation

Step-by-step guide to install the Kore 7th application on Windows OS.

Android Application Installation

Guide to install the Pacific Sun Kore 7th app on Android smartphones.

Starting and Connecting the Application

Windows Application Connection

Launching and establishing connection with the Kore 7th via Windows application.

Android Application Connection

Connecting the Kore 7th app to the doser via Android smartphone.

Core Device Configuration

Dosing Settings and Schedules

Configure daily doses, advanced schedules, and timing for each dosing pump.

Manual Control and Pump Calibration

Manually operate pumps, set flow modes, and perform calibration.

Liquid, ATO, and AWC Management

Manage liquid levels, ATO, and Automatic Water Changes (AWC).

kHLab and Water Parameter Monitoring

Configure kHLab for alkalinity tests, pH monitoring, and view dKH charts.

Calibration Procedures

kHLab Pump Calibration and Accuracy

Detailed methods for calibrating pumps and checking their accuracy.

pH Probe Setup and Calibration

Initial and multi-point calibration procedures for the pH probe.

Software and Firmware Management

Software and Firmware Upgrade

Steps for connecting, verifying COM port, and updating the Kore 7th firmware.

Troubleshooting Common Issues

Accuracy and Connectivity Problems

Solutions for inaccurate measurements, communication errors, and stirrer issues.

Pacific Sun Kore 7th Specifications

General IconGeneral
BrandPacific Sun
ModelKore 7th
CategoryMeasuring Instruments
LanguageEnglish